Submittal Sheet

UV100A ULTRAVIOLET SYSTEMS
11 68-0248—4
WARNING
UV Light Hazard.
Harmful to skin and eyes.
Can cause temporary or permanent loss of vision.
Never look at bulbs while illuminated.
View illumination only through light indicator located on
lamp handle.
To prevent exposure to ultraviolet light, disconnect
power ultraviolet system before servicing any part of
heating and air conditioning system.
9. Reconnect power to your UV System.
10. Verify that your ultraviolet lamps are operating by
viewing only through the lamp light indicator on the lamp
handle. Never look directly at your lamp while it is
illuminated.
11. Reconnect power to your heating and cooling system.
CAUTION
UV Lamp Burn Hazard.
Harmful to bare skin.
Can cause severe burns.
Disconnect power 15 minutes before removing
ultraviolet bulb(s).
Annual Bulb Replacement
Annual replacement of the bulb in your ultraviolet lamp is
required to maintain effectiveness:
1. Obtain the correct replacement bulb for your unit. See
Table 1.
2. Disconnect the power to your heating and cooling
system.
3. Unplug or turn off power to your UV System and allow
the bulbs to cool for at least 15 minutes.
4. Rotate the lamp handle counterclockwise and gently pull
the lamp handle to remove the bulb. See Fig. 5.
5. If you have a SnapLamp™ handle, follow steps 5 and 6;
otherwise, proceed to step 7. Grasp the SnapLamp™
handle in one hand and the lamp glass in the other and
pull straight apart. See Fig. 15.
Fig. 15. Disconnect lamp glass from SnapLamp™ handle.
6. Insert the new lamp glass into the SnapLamp™ handle
by aligning the key and pushing straight together. See
Fig. 16.
Fig. 16. Replace lamp glass in SnapLamp™ handle.
7. Insert the lamp handle into the base with the lamp light
indicator at the eleven o’clock position. Continue pushing
and gently rotating counterclockwise until the lamp
handle inserts fully into the base. See Fig. 13.
WARNING
UV Light Hazard.
Harmful to bare skin and eyes.
Can cause temporary or permanent loss of vision.
View illumination only through light indicator located on
lamp handle.
To prevent exposure to ultraviolet light, disconnect
power to ultraviolet system before servicing any part of
heating and air conditioning system.
8. Rotate the lamp handle clockwise until it snaps into place
with the lamp light indicator aligned with the raised
button on the unit cover. See Fig. 14.
9. Reconnect power to your UV System.
10. Verify that your ultraviolet lamp is operating by viewing
only through the lamp light indicator on the lamp
handle. Never look directly at your lamp while it is
illuminated.
11. Reconnect power to your heating and cooling system.
Table 1. Select a Replacement Bulb/Handle Assembly or
Replacement Bulb.
Unit Description
Replacement
Bulb/Handle
Assembly
SnapLamp™
Replacement
Bulb
UV100A1000
Air Treatment
System
UC100A1005 UC18W1004
UV100A1018
Air Treatment
System
UC100A1054
(two required)
UC36W1006
(two required)
UV100A1059
Surface Treatment
System
UC100A1054 UC36W1006
UV100A2008
Surface Treatment
System
UC100A1054 UC36W1006
M22851