Clean Comfort Spec Sheet

UV Air Purifier (24V) with AirBRIGHT™ Odor Absorption
UV2400U5000/UV2400U1000 UV Air Purification System
SPECIFICATION DATA
68-3104EFS-01
Specifications
Part Number: UV2400U5000 - UV + AirBRIGHT Odor Absorption Kit
UV2400U1000 - UV Kit
Lamp Wattage: 16W
Supply Voltage: 18 - 32 VAC; 50-60 Hz.
Amps: 0.68 A, 16 VA
Dimensions (See Fig. 1):
Width: 4.3 in.
Height: 5.2 in.
Length: 16.4 in.
Weight: 1.7 lbs (0.8 kg)
Shipping Dimensions:
Width: 5.2 in.
Height: 3.62 in.
Length: 22.8 in.
Weight: 2.3 lbs (1.0 kg)
Optional Parts:
AirBRIGHT Assembly UV2400XPCO1
Replacement Ballast UV2400XBAL1
Replacement Lamp UV2400XLAM1
Duct Board Adapter UV2400XDBA1
For more information call 1-800-468-1502 or visit our
website at customer.honeywell.com.
Application and Benefits
When installed at the air conditioner coil, the Air Purifier’s UV
irradiation helps to inhibit surface growth of micro-organism
contaminants such as mold from forming on the air conditioning
coil and drain pan. The presence of mold can lower the
efficiency of the cooling system and can allow unwanted odors
into the home. The AirBRIGHT Odor Absorber further purifies
the air passing through the system by reducing the odor-
causing Volatile Organic Compounds (VOCs) that can build
up in a home over time. The products are best used together
and combine to not only help cleanse the air but the UV light
also renews the AirBRIGHT system which virtually makes
AirBRIGHT maintenance free.
Job Name
Engineer
Mechanical Contractor
Contractor’s P.O. No.
Representative
Notes
UV Performance
UV Surface Treatment Effectiveness with a new lamp:
UV will reduce 99% of mold
1
on an air conditioning coil helping to
maintain system efficiency and airflow.
AirBRIGHT™ Performance
VOC Reduction with a new UV lamp: AirBRIGHT will reduce
VOC levels by over 90 percent
2
cleansing the air.
Lamp Life
Lamp should be changed 1/year or every 9000 hrs to maintain its
effectiveness
Fig. 1. UV2400U5000, dimensions in inches (mm).
1
• The device will reduce Serratia Marcescens by 99%+ during standard operation over a period of 24 hours, at a distance of 4.5 inches.
• The device will reduce Bacillus Subtilis by 99%+ during standard operation over a period of 24 hours, at a distance of 4.5 inches.
• The device will reduce Aspergillus Versicolor by 90%+ during standard operation over a period of 24 hours, at a distance of 4.5 inches.
(LMS Technologies, Inc. Report, November 2006.)
2
The device will reduce Decane and Toluene (Methylbenzene) levels by greater than 90% after 1.5 hours of standard operation in a controlled chamber test. (Air Quality Science Report 17183-04,
October 2011.)
2-1/2
(64)
M34858
4-19/64
(109)
5-13/64
(132)
1-11/32
(34)
16-3/8 (416)
Model(s) Qty.
UV2400U5000
UV2400U1000
Approval
Service
Tag. No.

Summary of content (4 pages)