Specifications

Combination Gas Controls
70-6910 111
Home
Controls Indoor Air Quality
Residential
Combustion Controls Hydronic Controls
Water
Controls Building Automation
Commercial
Components Pneumatic Controls
Industrial Combustion
Controls
VR8204 Intermittent Pilot Dual Automatic Valve Combination Gas
Controls
Combination gas controls for use in 24 Vac, gas-fired, intermittent
pilot appliances with capacities from 20 to 200 cfh.
Controls include manual valve, two automatic operators, servo
pressure regulator and pilot adjustment.
Use with S86F,H; S8600F,H and S8610 Control Modules.
Compact size.
Provide two automatic valves.
Solenoid operated first automatic valve opens on thermostat call for
heat; closes when call for heat ends.
Diaphragm operated second automatic valve opens under control of
regulator; closes if gas or power supply is interrupted.
Meet codes requiring dual safety shutoff.
Natural to LP and LP to Natural conversion kits available for
standard and slow opening gas valves.
All adjustments and wiring connections are accessible from top of
control.
ON-OFF lighting sequence.
Dimensions in inches (millimeters) Type: Single Stage
Body Pattern: Straight-through
Capacity @ 1 in. p.d. 150,000 BTU/hr; 20,000 BTU/hr minimum
Anticipator Setting: 0.5 A
Ignition Type: Intermittent Pilot
Pressure Ratings: 1/2 psi (3.5 kPa)
Pressure Tapping: 1/8 in. NPT with plug
Electrical Ratings: 24 Vac
Frequency: 60 Hz
Pilot Gas Outlet: Compression fitting for 1/4 in. OD tubing
Electrical Connections: 1/4 in. quick-connect male terminals
Mounting: 0 to 90 degrees in any direction from the upright position of
the gas control knob, including vertically.
Approvals:
American Gas Association: AGA Design Certificate: L2025006
Australian Gas Association: Australian Gas Assoc. Design
Certificate: 4214; Approved for Delta C Applications
Canadian Gas Association: CGA Design Certificate: L2025006
Underwriters Laboratories, Inc. UL Component Recognized: MH5323
M8151A
3-1/2
1-7/16
2-11/16 (69)
1
(25)
1/2
(13)
3-5/8 (91)
SWING
RADIUS
1/4 in. QUICK-
CONNECT
TERMINALS
1 (25)
1/2
(13)
4-1/2 (104)
PV
PV/MV
MV
(36)
(89)
Product Number
Type of
Gas
Opening
Characteristics
(standard, step)
Inlet/
Outlet
Size
(in.)
Pressure Regulator Setting
Ambient
Temperature
Range
Includes(psi) (kPa) (F) (C)
* VR8204A2076 Natural Standard 1/2 in. x
1/2 in.
3.5 in. wc 0.87 kPa 0 F to
175 F
-18 C to
+79 C
One 3/4 in. straight flange
One 1/2 in. x 3/8 in. reducer
bushing
Natural to LP Conversion Kit
VR8204C1019 Natural Step Opening 1/2 in. x
1/2 in.
Full Rate:
3.5 in. wc;
Step Setting:
0.9 in. wc
Full Rate:
0.87 kPa;
Step Setting:
0.22 kPa
0 F to
175 F
-18 C to
+79 C
VR8204H1006 Natural Slow Opening 1/2 in. x
1/2 in.
3.5 in. wc 0.87 kPa 0 F to
175 F
-18 C to
+79 C
* VR8204M1091 Natural Standard 1/2 in. x
1/2 in.
3.5 in. wc 0.87 kPa -40 F to
+175 F
-40 C to
+79 C
One 3/4 in. straight flange
One 1/2 in. x 3/8 in. reducer
bushing
Natural to LP Conversion Kit
* TRADELINE models • SUPER TRADELINE models