Specifications

Combination Gas Controls
112 customer.honeywell.com 70-6910
VR8245 Intermittent Pilot Combination Gas Control
These universal electronic ignition gas controls are used in gas-
fired appliances with capacities up to 150 cu ft/hour at 1 inch wc
pressure drop (4.2 cu m/hour at 0.25 kPa) for natural gas. The
VR8245M will operate with a direct spark (DSI), hot surface (HSI) or
intermittent pilot ignition. The control includes a manual valve, two
automatic operators, a pressure regulator, pilot adjustment, pilot
plug and ignition adapter.
Type: Single Stage
Body Pattern: Straight-through
Capacity @ 1 in. p.d. 150,000 BTU/hr
Ignition Type: Intermittent Pilot
Ambient Temperature Range: -40 F to +175 F (-40 C to +79 C)
Pressure Ratings: 1/2 psi (3.5 kPa)
Electrical Ratings: 24 Vac
Frequency: 60 Hz, 50 Hz
Mounting: 0 to 90 degrees in any direction from the upright position of
the gas control knob, including vertically.
Product Number Type of Gas
Opening Characteristics
(standard, step)
Inlet/Outlet
Size (in.)
Pressure Regulator Setting
Includes(psi) (kPa)
VR8245M2530 Natural or LP Standard 1/2 in. x 1/2 in. 3.5 in. wc 0.9 kPa One 1/2 in. x 3/8 in. reducer
bushing
Natural to LP Conversion Kit