V400 Line Voltage; V800 Low Voltage Combination Gas Controls
Used on gas fired standing pilot appliances with 30 mV
thermocouple. These gas controls include a manual gas valve,
safety shutoff, single millivoltage automatic operator, and pressure
regulator, pilot gas filter and flow adjustment, pressure tapping,
and thermocouple connector. V800 is used on 24V systems.
Include pilot flow adjustment screw.
Easy to install, adjust and service; all adjustments and connections
are accessible from top of control.
Add separate energy cutoff (ECO) where codes call for dual safety
shutoff.
Complete safety shutoff on pilot flame failure.
LITE-RITE (OFF-PILOT-ON) lighting sequence.
ECO connector for V800 models. Part No. 392451-1.
Dimensions in inches (millimeters)
Type: Single Stage
Body Pattern: Straight-through, multi-tapped with 1/2 in. right and left
outlets plugged
Capacity @ 1 in. p.d. 335,000 BTU/hr; 295,000 BTU/hr minimum
Ignition Type: Standing Pilot
Ambient Temperature Range: 32 F to 175 F (0 C to 79 C)
Pressure Ratings: 1/2 psi (3.5 kPa)
Pressure Tapping: 1/8 in. NPT with plug
Frequency: 60 Hz
Pilot Gas Outlet: Compression fitting for 1/4 in. OD tubing
Mounting: 0 to 90 degrees in any direction from the upright position of
the gas control knob, including vertically.
Approvals:
American Gas Association: AGA Design Certified; File No. L2025003,
CGA Design Certified; File No. L2025003, UL Component
Recognized.
Underwriters Laboratories, Inc. UL Component Recognized.
PILOT CONNECTION
COMP. FITTING
FOR 1/4 O.D. TUBING
PRESSURE
TAP 1/8 NPT
MOUNTING
HOLES (2)
NO. 10-32 X
.25 DEEP
3-3/4 (95)
SWING
RADIUS
3-3/4 (95)
SWING
RADIUS
5/16 (8)
3-1/2
(89)
1-1/4
(32)
4-3/4
(121)
5/16 (8)
5/16 (8)
2-9/16
(65)
4-1/16 (103)
3-3/16 (81)
1-7/16
(37)
1-3/16
(37)
1-7/8
(48)
WITH V5306 (ILLUSTRATED), V5307 OR 5390 PRESSURE REGULATOR: 24V MODELS–3-1/2 (89), 120V MODEL–3-5/8 (92)
MANUAL MODELS–2-13/16 (71), FOR V5308 ADD 5/8 (16) TO DIMENSIONS GIVEN.
SIDE OUTLETS–LEFT AND RIGHT HAND. STANDARD ONLY ON TRADELINE MODELS.
CONTROL WITH 24V VALVE OPERATOR SHOWN. LINE VOLT MODEL HAS COVER FOR CONDUIT CONNECTION (TOP SURFACE).
ECO CONNECTOR ON STANDARD CAPACITY V800 ONLY.
1
1
2
2
3
3
4
4
M16547A
Product Number
Type
of Gas
Opening
Characteristics
(standard,
step)
Inlet/
Outlet
Size
(in.)
Pressure Regulator Setting
Electrical
Ratings Includes(psi) (kPa)
V400A1095 Natural Standard 3/4 in. x
3/4 in.
3.5 in. wc 0.87 kPa 120 Vac Two 3/4 x 1/2 in.; One 1/2 x 3/8 in.
Reducer Bushing/Adapters
V400C1036 Natural Step Opening 3/4 in. x
3/4 in.
Full Rate: 3.5 in. wc;
Step Setting: 0.7 in. wc
Full Rate: 0.87 kPa;
Step Setting: 0.17 kPa
120 Vac
* V800A1070 Natural
or LP
Standard 1/2 in. x
3/4 in.
3.5 in. wc 0.87 kPa 24 Vac One 1/2 in. x 3/8 in. reducer bushing,
One 3/4 in. x 1/2 in. reducer bushing,
Q340 Thermocouple,
Natural to LP Conversion Kit
* TRADELINE models • SUPER TRADELINE models