Specifications

Combination Gas Controls
70-6910 113
Home
Controls Indoor Air Quality
Residential
Combustion Controls Hydronic Controls
Water
Controls Building Automation
Commercial
Components Pneumatic Controls
Industrial Combustion
Controls
VR8304 Intermittent Pilot Dual Automatic Valve Combination Gas
Control
Combination gas control for use in 24 Vac, gas-fired, intermittent
pilot appliances with capacities from 30 to 415 cfh.
Controls include safety shutoff, manual valve, two automatic
operators, pressure regulator and pilot adjustment.
Use with S86F,H; S860D; S8600F,H; S8610 and S90A,B Control
Modules.
Compact size.
Provide two automatic valves. Solenoid operated first automatic
valve opens on thermostat call for heat; closes when call for heat
ends.
Diaphragm-operated second automatic valve opens under control of
regulator; closes if gas or power supply is interrupted.
Meet codes requiring dual safety shutoff.
Natural to LP and LP to Natural conversion kits available for
standard and slow opening gas valves.
All adjustments, wiring connections and pilot outlet are accessible
from top of control.
Adjustable servo regulator effectively maintains almost constant gas
output pressure under wide fluctuations in gas supply pressure.
Compatible with ECO connector.
ON-OFF lighting sequence.
Dimensions in inches (millimeters) Type: Single Stage
Body Pattern: Straight-through
Capacity @ 1 in. p.d. 300,000 BTU/hr; 30,000 BTU/hr minimum
Anticipator Setting: 0.7 A
Ignition Type: Intermittent Pilot
Pressure Ratings: 1/2 psi (3.5 kPa)
Pressure Tapping: 1/8 in. NPT with plug
Electrical Ratings: 24 Vac
Frequency: 60 Hz
Pilot Gas Outlet: Compression fitting for 1/4 in. OD tubing
Electrical Connections: 1/4 in. quick-connect male terminals
Mounting: 0 to 90 degrees in any direction from the upright position of
the gas control knob, including vertically.
Approvals:
American Gas Association: AGA Design Certified: File No. L2025007.
Canadian Gas Association: CGA Design Certified: File No. L2025007.
Underwriters Laboratories, Inc. UL Component Recognized.
M7495A
1
(25)
4 in. (102)
SWING
RADIUS
1/4 in. QUICK-
CONNECT
TERMINALS
1 (25)
(13)
(13)
PV
PV/MV
MV
4-1/16 (104)
1/2
1/2
2-11/16 (69)
3-15/16
(99)
1-7/16
(36)
Product Number
Type of
Gas
Opening
Character-
istics
(standard,
step)
Inlet/
Outlet
Size
(in.)
Pressure Regulator Setting
Ambient
Temperature
Range
Includes(psi) (kPa) (F) (C)
VR8304H4503 Natural Slow
Opening
3/4 in. x
3/4 in.
3.5 in. wc 0.87 kPa 0 F to
175 F
-18 C to
+79 C
393691 Natural to LP gas
conversion kit.
VR8304M2501 Natural Standard 1/2 in. x
1/2 in.
3.5 in. wc 0.87 kPa -40 F to
+175 F
-40 C to
+79 C
393691 Natural to LP gas
conversion kit.
* VR8304M3509 Natural Standard 1/2 in. x
3/4 in.
3.5 in. wc 0.87 kPa -40 F to
+175 F
-40 C to
+79 C
One 3/4 in. x 1/2 in.
reducer bushing; 393691
Natural to LP gas
conversion kit.
* VR8304M4507 Natural Standard 3/4 in. x
3/4 in.
3.5 in. wc 0.87 kPa -40 F to
+175 F
-40 C to
+79 C
Two 3/4 in. x 1/2 in.
reducer bushing; 393691
Natural to LP gas
conversion kit.
VR8304P4330 LP Step
Opening
3/4 in. x
3/4 in.
Full Rate: 10.0 in. wc;
Step Setting: 2.5 in. wc
Full Rate: 2.49 kPa;
Step Setting: 0.62 kPa
-40 F to
+175 F
-40 C to
+79 C
VR8304P4504 Natural Step
Opening
3/4 in. x
3/4 in.
Full Rate: 3.5 in. wc;
Step Setting: 0.9 in. wc
Full Rate: 0.87 kPa;
Step Setting: 0.22 kPa
-40 F to
+175 F
-40 C to
+79 C
VR8304Q4511 Natural Standard 3/4 in. x
3/4 in.
1.7 in. wc low; 3.5 in. wc
high
0.48 kPa low; 0.87 kPa
high
-40 F to
+175 F
-40 C to
+79 C
Natural to LP Conversion
Kit Two 3/4 x 1/2 in.
reducer bushings
* TRADELINE models • SUPER TRADELINE models