Video Recorder User Manual

Programming Function Blocks and Features
Video Recorder – User Manual 136
Scaling
The output CVn OV is a linear scaling of the input using the specified limits.
Table 4-43 describes the Scaling prompts. See Table 4-2 for additional prompts.
Table 4-43 Scaling Prompts
Prompt Range/Selections Definition
IN LOW LIMIT
IN HIGH LIMIT
OFF or number Enter limits of input to be scaled.
RANGE LOW
RANGE HIGH
OFF or number Enter the output’s scaling values and display limits. Output
is not clamped or flashed when it exceeds these limits.
INPUT OFF, analog parameter,
number
Input to be scaled according to the limits.