MS4980 Area Imaging Scanner Installation and User's Guide
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
Table of Contents Introduction Product Overview ............................................................................................. 1 Base Kit ............................................................................................................ 2 Optional Accessories........................................................................................ 2 Scanner Components....................................................................................... 3 Maintenance..................
Configuration and Upgrades Configuration Modes ...................................................................................... 29 Upgrading the Firmware ................................................................................. 30 Scanner and Cable Terminations Scanner Pinout............................................................................................... 31 Cable Connector Configurations .................................................................... 33 Limited Warranty ...
Introduction Product Overview The MS4980 is a high performance area imaging bar code scanner packed into a small yet rugged form factor. The scanner features a high-resolution CMOS imaging sensor to deliver excellent omnidirectional 1D, PDF417 and 2D bar code scan performance, optical character recognition (OCR) and image capture.
Basic Kit Part # Description MS4980 Area Imaging Bar Code Scanner 00-02544 MetroSelect® Single-Line Configuration Guide* 00-05252 Area Imaging Bar Code Scanner Supplemental Configuration Guide* 70-79037 MS4980 Scanner Installation and User’s Guide* *Available for download from www.honeywellaidc.com Optional Accessories Part # Description AC to DC Power Transformer – Regulated 5.2VDC @ 1A output.
Scanner Components Figure 1. Scanner Components Item No. Description Button Camera Imager Infrared Sensor (IR) Targeting Window Area Illumination Cable Connection (15-pin HD-22 D-type connector) M3 Mounting Holes White LED Blue LED Maintenance Smudges and dirt on the unit’s window can interfere with the unit’s performance. If the window requires cleaning, use only a mild glass cleaner containing no ammonia.
Cable Installation Important: If the cable is not fully attached, the unit may power intermittently. Figure 2. Cable Installation 1. Insert the 15-pin D-type connector end of the cable into the socket on the MS4980. 2. Rotate the two screws clockwise to tighten. 3. Gently pull on the cable strain relief to insure the cable is installed. Cable Removal Before removing the cable from the scanner, turn off power on the host system and disconnect the power supply, if applicable. Figure 3.
Labels Every scanner has a label located on the underside of the unit. The label contains important information such as the unit’s date of manufacture, serial number, CE and caution information. Figure 4 provides an example of the label. Figure 4 . Label Example Caution: To maintain compliance with applicable standards, all circuits connected to the imager must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA C22.2 No.
6
Installation RS232 1. Turn off the host device. 2. Plug the 15-pin socket end of the cable into the 15-pin D-Type connector on the MS4980 (see page 4). 3. Connect the 9-pin D-type connector of the communication cable to the proper COM port of the host device. 4. Plug the power supply into the power jack on the PowerLink cable. 5. Check the AC input requirements of the power supply to verify the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.
Keyboard Wedge 1. Turn off the host device. 2. Plug the 15-pin socket end of the cable into the 15-pin D-Type connector on the MS4980 (see page 4). 3. Disconnect the keyboard from the host device. 4. Connect the “Y” ends of the communication cable to the keyboard and keyboard port on the host device. If necessary, use the male/female adapter cable supplied with the scanner for proper connections. 5. Plug the power supply into the power jack on the PowerLink cable. 6.
USB (Powered by the Host Device) 1. Turn off the host device. 2. Plug the 15-pin socket end of the USB cable into the 15-pin D-Type connector on the MS4980 (see page 4). 3. Plug the USB end of the cable into the host’s USB port. 4. Turn on the host device. 5. The MS4980 will start to initialize. The white and blue LED will alternately fade on and off for approximately three seconds.
USB (Powered by External Power Supply) 1. Turn off the host device. 2. Plug the 15-pin socket end of the cable into the 15-pin D-Type connector on the MS4980 (see page 4). 3. Plug the USB end of the cable into the host’s USB port. 4. Plug the power supply into the power jack on the PowerLink cable. 5. Check the AC input requirements of the power supply to verify the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible. 6.
Mounting Specifications The MS4980 has three M3 x 0.5 mm threaded inserts on the bottom of the scanner for mounting with screws. Figure 10.
12
Operation Modes of Operation The MS4980 supports two standard modes of operation for scanning bar codes, automatic activation and manual activation scanning. Scanning while in the automatic activation mode can occur in either one of two configurable options, pass-through or presentation. Both the pass-through and the presentation options are enabled by default.
Manual Activation Decodes ALL 1D, PDF and 2D matrix codes Scanning Method: 1. Press the button one time to activate linear targeting. 2. Align the linear targeting line over the desired bar code. Note: When scanning 1D programming bar codes, the bar code must be presented to the scanner in the correct orientation, see Figure 11. PDF and 2D matrix codes may be presented in any orientation. Figure 11. 1D Programming Bar Code Orientation 3. Press the button a second time to decode and send the data.
Audible Indicators When the MS4980 is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, six alternate tones and no tone). To change the tone, refer to the MetroSelect Single-Line Configuration Guide, PN 00-02544, or MetroSet2’s help files. One Beep When the scanner successfully reads a bar code the unit will beep once and the white LED will flash once indicating data has been transmitted successfully.
Visual Indicators The scanner has blue and white LED indicators on either side of the button on the top of the unit. When the scanner is on, the intensity of the LED and the flashing or stationary activity of the LEDs, indicates the status of the current scan and the diagnostic scanner. No LEDs are Illuminated Figure 12. The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. Steady Low Intensity Blue The scanner is in stand-by mode.
Failure Modes Long Razzberry Tone – During Power Up Failed to initialize or configure the scanner. If the scanner does not respond after reconfiguration, return the scanner for repair. Short Razzberry Tone – During Scanning An Invalid bar code has been scanned when in configuration mode.
Field of View Figure 13. MS4980 Field of View Specifications are subject to can without notice.
Depth of Field Minimum Bar Code Element Width 1D PDF A B C D E F mm .132 .190 .264 .330 .190 .381 mils 5.2 7.5 10.4 13 7.5 15 Figure 14. Depth of Field Note: Standard models ship with the ability to read all 1D, PDF and 2D bar codes. Decoding and functional capability is limited and units will not support key features including, but not limited to, the ability to decode PDF, 2D or OCR fonts without proper limited use licenses provided by Honeywell.
IR Activation Range The MS4980 scanner has a built in object detection sensor that instantly turns on the scanner when an object is presented within the scanner’s IR activation area. Figure 15. IR Activation Area Specifications are subject to can without notice.
Troubleshooting Guide The following guide is for reference purposes only. Contact a customer service representative to preserve the limited warranty terms, see page 45. All Interfaces Symptoms Possible Causes Solution No power is being supplied to the scanner. Check transformer, outlet and power strip. Make sure the cable is plugged into the scanner. No power is being supplied to the scanner from the host. Some host systems cannot supply enough current to power the MS4980.
Symptoms Possible Causes Solution The unit powers up, but does not The beeper is disabled beep when bar and no tone is selected. code is scanned. Enable the beeper and select a tone. The unit powers up, but does not scan and/or beep. The bar code symbology trying to be scanned is not enabled. UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128, Codabar and PDF are enabled by default. Verify that the type of bar code being read has been selected. The unit powers up, but does not scan and/or beep.
Symptoms The unit beeps at some bar codes and NOT for others of the same bar code symbology. The unit scans the bar code but there is no data. Possible Causes Solution The bar code may have been printed incorrectly. Check if it is a check digit/character/or border problem. The scanner is not configured correctly for this type of bar code. Check if check digits are set properly. The minimum symbol length setting does not work with the bar code. Check if the correct minimum symbol length is set.
Symptoms The unit scans but the data is not correct. Possible Causes Solution The scanner and host Check that the scanner and the may not be configured for host are configured for the the same interface same interface parameters. parameters. The following item is only relevant for an RS232 interface. The unit powers up OK and scans The com port at the host OK but does not is not working or not communicate configured properly. properly with the host.
Design Specifications Operational Light Source: Pulse Duration: Maximum Output of LED: Depth of Scan Field: LED 645 nm ± 7.5 nm Up to 4 mS (Default) 2.63 mW 40 mm – 300 mm (1.57" – 11.8") for 0.33 mm (13 mil) 40 mm x 30 mm (1.57" x 1.18") @ 40mm (1.
Electrical Input Voltage: 5.2 VDC ± 0.25V Power: Current: DC Transformers: RS232, USB w/Power Jack, Keyboard Wedge USB Host Powered Peak 2.1 W (Typical) 1.9 W (Typical) Operating 1.7 W (Typical) 1.7 W (Typical) Idle 1.2 W (Typical) 1.2 W (Typical) Peak 398 mA (Typical) 360 mA (Typical) Operating 331 mA (Typical) 317 mA (Typical) Idle 230 mA (Typical) 230 mA (Typical) Peak Values of at least 1 ms in width. Class II: 5.
Applications and Protocols The model number on each scanner includes the scanner number. Version Identifier Scanner Communication Protocol(s) Interfaces supported include: MS4980 124 RS232 (TXD, RXD, RTS, CTS) Keyboard Wedge USB USB is configurable for Keyboard Emulation Mode, Bi-Directional Serial Emulation Mode or IBM OEM. The default USB setting is Keyboard Emulation Mode. The following are the most important selectable options specific to the keyboard wedge.
28
Configuration and Upgrades Configuration Modes The MS4980 has three modes of configuration. Bar Codes The MS4980 can be configured by scanning the bar codes included in the MetroSelect Single-Line Configuration Guide or the Area Imaging Supplemental Configuration Guide shipped with the area imager. The manuals are available for download at www.honeywellaidc.com. MetroSet2 This user-friendly Windows-based configuration program allows you to simply ‘point-and-click’ at the desired scanner options.
Upgrading the Firmware The MS4980 scanner is part of Honeywell’s line of scanners with flash upgradeable firmware. The upgrade process requires a new firmware file supplied to the customer by a customer service representative and the MetroSet2 software. A personal computer running Windows 95 or greater with an available RS232 serial or USB port is required to complete the upgrade. Note: Do not use the standard cable supplied with Keyboard Wedge MS4980 interface kits for firmware upgrades.
Scanner and Cable Terminations Scanner Pinout Figure 16.
Figure 17.
Cable Connector Configurations (Host End) RS232 PowerLink Cable PN 52-52557x-3 Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 No Connect 5 Power/Signal Ground 6 Reserved 7 CTS Input 8 RTS Output 9 5VDC Host 9-Pin D-Type Connector USB PowerLink Cable PN 52-52559x-3 Pin 1 2 3 4 Shield Function PC +5V DD+ Ground Shield Non-Locking, Type A USB Direct Cable PN 52-52559x-N-3 Pin 1 2 3 4 Function +5VDC/Power DD+ Ground Non-Locking, Type A 33
Keyboard Wedge PowerLink Cable PN 52-52558x-3 Pin 1 2 3 4 5 Pin 1 2 3 4 5 6 Function Keyboard Clock Keyboard Data No Connect Power Ground +5 Volts DC Function PC Data No Connect Power Ground +5 Volts DC PC Clock No Connect 5-Pin DIN, Female 6-Pin DIN, Male An adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other will be supplied.
Limited Warranty Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in materials and workmanship and to conform to HII’s published specifications applicable to the products purchased at the time of shipment.
All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unenforceable, such determination shall not affect the validity of enforceability of the other provisions hereof. Use of any peripherals not provided by the manufacturer may result in damage not covered by this warranty. This includes but is not limited to: cables, power supplies, cradles, and docking stations. HII extends these warranties only to the first endusers of the products.
Regulatory Compliance Safety ITE Equipment IEC 60950-1, EN 60950-1 LED Class 1 LED Product: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Under no circumstances should the customer attempt to service the LED scanner. Never attempt to look at the LED beam, even if the scanner appears to be nonfunctional.
Wenn Sie dies tun, können Sie sich einer gefährlichen Licht emittierender Diodenstrahlung aussetzen. Der Einsatz optischer Geräte mit dieser Laserausrüstung erhöht das Risiko einer Sehschädigung. Attenzione L'utilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel presente Manuale può provocare delle rischiose esposizioni radiattive. Il cliente non deve assolutamente tentare di riparare egli stesso lo scanner LED (o diodo emettitore di luce).
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Notice This Class A digital apparatus complies with Canadian ICES-003. Remarque Cet appareil numérique de classe A est conforme à la norme canadienne NMB-003. European Standard Warning This is a class A product.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Class B Devices The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner ne dépassant pas 3 métres (9.
Patents For patent information, please refer to www.honeywellaidc.com/patents.
42
Index A flash ROM ................................... 30 AC ...........................................2, 26 accessories ...................................2 adapter ....................................2, 34 audible indicator .............. 13–17, 30 I B bar code .................... 19, 21–24, 29 beep .................... 13–17, 21–24, 30 blue LED.......................... 13–17, 30 button ....................................14, 30 C cable adapter.......................................2 communication..
R razz ........................... 13–17, 21–24 repair ...........................................36 RMA ............................................36 RS232 ........................ see interface S transformer.............................. 2, 26 troubleshooting ..................... 21–24 U UL ................................................. 5 upgrade....................................... 30 USB ............................see interface safety...........................................37 service ......
Customer Support Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nearest technical support office: North America/Canada Telephone: (800) 782-4263 E-mail: hsmnasupport@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 E-mail: hsmlasupport@honeywell.com Brazil Telephone: +55 (21) 3535-9100 Fax: +55 (21) 3535-9105 E-mail: brsuporte@honeywell.
Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product. North America Telephone: (800) 782-4263 E-mail: hsmnaservice@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 Fax: (239) 263-9689 E-mail: laservice@honeywell.
Honeywell Scanning & Mobility 90 Coles Road Blackwood, NJ 08012 70-79037 Rev C October 2009