Technical Manual

XNX Universal Transmitter
Section 6 - Specications
128
Electrical
Operating Voltage
EC/mV: 16V to 32V (24V nominal) ** Startup/Normal values **
IR: 18V to 32V (24V nominal) ** Startup/Normal values **
Power
Consumption
Conguration
Max
Power
Inrush
XNX EC 6.2 w <1A, <10ms@24VDC
XNX mV 6.5 w <750mA <2ms@24VDC
XNX IR (Optima) 9.7w <1A, <10ms@24VDC
XNX IR (Excel) 13.2w <1A, <10ms@24VDC
Termination
Crimp style pluggable with retaining screws, 12-28 AWG (2.5 to 0.5mm
2
) with
Shorting Jumpers: 14-28 AWG (2.0 to 0.5mm
2
)
NOTE:
To maintain EMC integrity, wiring must be shielded by either an integral shield
or run through conduit or pipe. Shield should provide 90% coverage
20 mA Signal
HART
®
over 3-wire 4-20mA (sink, source, or isolated) compliant with NAMUR
NE43
Cable Ports
5 – (2 right, 2 left, 1 bottom) Available in ¾” NPT, or M25
Recommended
Cable
See Section 2.2.2 Distance Considerations for Installation.
Construction
Material
LM25 Aluminum, (SS316 painted optional)
Dimensions
159 x 197 x 113.8 mm / 6.138 x 7.75 x 4.48 inches
Weight
2.27 kg (5 lb) Aluminum
5 kg (11 lb) Stainless
Mounting
XNX
®
Enclosure
Integral Mounting Lugs for Wall- or Optional Pipe-Mount, Optional Wall/Ceiling
Bracket
User Interface
Standard
Custom Backlit LCD, magnetic wand access
Optional
HART Handheld with IS Port
Environmental - Transmitter Operating
IP Rating
IP66
Temperature*
-40°C to +65°C / -40°F to +149°F
Humidity
0 to 99% RH non-condensing
*Operating temperatures will be limited by the sensors. See tables 6.2.2, 6.2.3, and 6.2.4 for more
information.
Environmental - Transmitter Storage
Temperature
-40°C to +65°C / -40°F to +149°F
Humidity
0 to 99% RH non-condensing
Unpowered battery life: (Real Time Clock) 3 years at rated storage temperature
6.1 Product Specications