Technical Manual

XNX Universal Transmitter
Section 2 - Installation and Operation
42
7. Mount the remote sensor junction box ensuring enough
roombelowtotthesensorandweatherproofcover.See
control drawing 3000E3157 in Section 7.2forspecic
mounting information.
8. Attach the cable to the remote terminal box via the gland
provided.
9. Make the wiring connections as shown in Figure 43.
10. Fit the Terminal box lid.
11. Plug the sensor into the socket at the bottom of the terminal
box.
12. Fitthesensorretainer,tightenthelockingscrew,andt
the weatherproof cover.
13. Calibrate the sensor following the procedure in Section
3.2.1.
Black
1 Yellow
Connections
Pin # Color
2 Green
3 Blue
4 White
5 Red
6
Sensor Cartridge
Weatherproof Cap
Sensor Retainer
Sensor Mounted to Remote Sensor Kit
Figure 44. Installing Remote Sensor Mounting Kit