GasAlertMaxXT II
Activating/Deactivating the Detector
Activating/Deactivating the Detector
Note
Ensure the diffusion cover is attached prior to activating the
detector to verify the pump is working correctly.
To activate the detector, press C in a safe area that is free of hazardous
gas. Attach any pump accessories to the detector prior to activating the
detector.
To deactivate the detector, press and hold C until the OFF countdown
completes.
a Caution
The maximum hose length for sampling is 75 ft (22m).
Startup Tests
When the detector is activated, it performs several startup tests. Confirm
the following tests occur.
Battery Test
The detector performs a battery test during startup. If the battery has
insufficient power to operate, the following screens displays before
deactivating.
Recharge the battery for 6 hours and then reactivate the detector.
Refer to Charging the Battery
.
Audible/Visual Test
1. All of the LCD elements display simultaneously as the
detector beeps, flashes, vibrates, and activates the
backlight.