EIM Installation Guide 2012

2
Prestige/VisionPRO with RedLINK: Mount the thermostat and wire to C and
R terminals of the Equipment Interface Module (EIM), or to a separate 24 volt
transformer (not provided).
NOTE: When the VisionPRO with RedLINK thermostat is used with the EIM, the
relays in the thermostat do not function.
MCR34049A
R
C
Y
Y2
G
W
O/B
W2
AUX1
W3
AUX2
A
L/A
Strip 1/4”
insulation,
then insert
wires as
shown.
Use screws & anchors as appropriate for the mounting surface. Mount the EIM near
the HVAC equipment, or on the equipment itself.
CONNECT
CONNECTED
NOTE: If you install more than one thermostat
and EIM, the EIMs must be at least 2 feet
apart.
NOTE: If you are installing discharge and
return air sensors, refer to the mounting
instructions in the Alerts and Delta T
Diagnostics Installation Instructions packed
with the Prestige IAQ kit.
If an EIM is mounted inside a metal cabinet, it is
recommended to use a THM4000R1000 Wireless
Adapter for extended wireless range. Mount the
Wireless Adapter outside the metal cabinet and
connect to the ABCD terminals at the EIM.
S1
S1
W
Y
G
W2
Y2
A
S1
S1
O/B
Y
G
AUX
-E
Y2
L/A
K
RC
R
U1
U1
U2
U2
C
CONVENTIONAL
HEAT PUMP
1
2
Install thermostat
Install equipment interface module
EIM
A
B
C
D
WIRELESS
ADAPTER
CONNECT
POWER
THM4000R
CONNECTED
WIRELESS SETUP