TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
The fan seems
louder than it should
CFM too great
Be sure the CFM rating on the fan
matches the size of your room
Damper not working properly or
damaged
Check damper to ensure it is opening
and closing properly. If the damper
has become damaged, please call
Customer Service
Bend in duct too close to fan discharge
Be sure you do not have any sharp
bends in duct closer than 18 in. to the
fan discharge
Fan discharge reduced to t smaller
duct
Use recommended size ducting to
reduce fan noise
Fan body not securely attached
Be sure the fan is securely attached
to your ceiling joists
The fan is not
clearing the room
Insufcient intake airow within room
Be sure a door or window is slightly
ajar or opened to allow airow. The
fan is not able to draw air out of the
room without enough airow to draw
from
Insufcient CFM
Be sure the CFM rating on the fan
matches the requirements for your
room size
NOTE: Using a tissue is not an
accurate method for determining if
the fan is operating properly. If the
fan clears steam from the room
within approximately 15 minutes of
completeing your shower, then the
fan is operating properly
CARE AND MAINTENANCE
WARNING: Disconnect power supply before servicing.
See SAFETY INFORMATION before proceeding. Routine maintenance should be done at least once
a year.
Never use solvents, thinner or harsh chemicals for cleaning the fan.
• Do not allow water to enter the motor.
• Do not immerse metal parts in water.