Operation Manual

In addition, in both the text section and the illustrated section
at the points where the operator menus are explained, the
following symbol is shown that indicates the factory settings:
Factory setting
Abbreviations used1.5
Colour code for cables, single conductors and
components
The abbreviations of the colours for identifying the cables,
conductors and components comply with the international
colour code according to IEC 757:
BK Black RD Red
BN Brown WH White
GN Green YE Yellow
2 Safety Instructions
Intended use2.1
The hinged gate is designed and intended exclusively for the
operation of smooth-running hinged gates in the domestic,
non-commercial sector. The maximum permissible gate size
and maximum weight must not be exceeded. The gate must
be easy to open and close by hand.
Regional wind loads must be taken into account if using gate
infills (EN 13241-1).
Note the manufacturer's specifications regarding the gate and
operator combination. Potential hazards as outlined in
DIN EN 13241-1 are avoided by construction and fitting
according to our guidelines.
Gate systems that are located in a public area and only have
one protective device, such as a force limit, may only be
operated under supervision.
Inappropriate use2.2
Continuous operation and use in the commercial sector is
prohibited. The operator is not designed for use with sluggish
gates. Use on gates with a gradient or slope is not permitted.
Fitter qualification2.3
Only correct fitting and maintenance in compliance with the
instructions by a competent/specialist company or a
competent/qualified person ensures safe and flawless
operation of the system. According to EN 12635, a specialist
is a person with suitable training, specialist knowledge and
practical experience sufficient to correctly and safely fit, test,
and maintain a gate system.
Safety instructions for fitting, maintenance, 2.4
repairs and disassembly of the gate system
WARNING
Danger of injury due to unexpected gate travel
See warning in section
7
Fitting, maintenance, repairs, and disassembly of the gate
system and gate operator must be performed by a specialist.
In the event of a failure of the gate system or the
operator, a specialist must be commissioned immediately
for the inspection or repair work.
Safety instructions for fitting2.5
The specialist carrying out the work must ensure that
installation is conducted in compliance with the prevailing
national job safety rules and regulations and those governing
the operation of electrical equipment. The relevant national
directives must be observed. Potential hazards as outlined in
DIN EN 13241-1 are avoided by construction and fitting
according to our guidelines.
After fitting has been completed, the installer of the gate
system must declare conformity with DIN EN 13241-1 in
accordance with the scope of application.
DANGER
Mains voltage
See warning in section
3.4
WARNING
Danger of injury due to damaged components
See warning instructions Section
3.1
Unsuitable fixing material
See warning in section
3.2
Danger of injury due to unwanted gate travel
See warning in Section
3.3
Safety instructions for initial start-up and for 2.6
operation
WARNING
Danger of injury during gate travel
See warning in sections
4 and 6
Danger of injuries due to faulty safety equipment
See warning in sections
4.1.5 and 4.2.8
Danger of injury due to too-high force limit
See warning in section
4.3.1
Safety instructions for using the hand 2.7
transmitter
WARNING
Danger of injury during gate travel
See warning in section
5.1
CAUTION
Danger of injuries due to unintended gate travel
See warning in section
5.1
Safety instructions for inspection and 2.8
maintenance
WARNING
Danger of injury due to unexpected gate travel
See warning in section
7