Operation Manual

See Figure
11.2
6 ON 7 OFF Operator
Automatic timed closing, pre-
warning time only for
automatic timed closing
Option relay
Relay clocks rapidly during the
pre-warning time, normally
during the travel phase and is
OFF during the hold-open
phase.
See Figure
11.3
6 OFF 7 ON Operator
Warning phase for every gate
travel without automatic timed
closing
Option relay
Relay clocks rapidly during the
pre-warning time and normally
during the travel phase
See Figure
11.4
6 ON 7 ON Operator
Automatic timed closing, pre-
warning time for each gate
movement
Option relay
Relay clocks rapidly during the
pre-warning time, normally
during the travel phase and is
OFF during the hold-open
phase.
NOTE:
Automatic timed closing is only possible from the OPEN
end-of-travel position. If the force limit is activated during
closing, the gate briefly reverses in the OPEN direction and
stops. If the photocell is activated during closing, the gate
reverses into the OPEN end-of-travel position and automatic
timed closing is started again.
4.6.2 Slow travel speed
If the measured force is too high when the potentiometer
setting for the force limit is 0%, it can be reduced via a lower
travel speed.
To reduce the travel speed:
Set DIL switch1. 8 to ON.
8 ON Slow travel speed for all runs
8 OFF
Normal travel speed for all runs
Perform three successive force learning runs 2.
(see section 4.3).
Check the force again with a force measuring device.3.
5 Radio
5.1 Hand transmitter RSC 2
WARNING
Danger of injury during gate travel
Persons may be injured by gate travel if
the hand transmitter is actuated.
Make sure that the hand
transmitters are kept away from
children and can only be used by
people who have been instructed
on how the remote-control gate
functions!
If the gate has only one safety
feature, only operate the hand
transmitter if you are within sight of
the gate!
Only drive or pass through remote
control gate systems if the gate is in
the OPEN end-of-travel position!
Please note that unwanted gate
cycles may occur if a hand
transmitter button is accidentally
pressed (e.g. if stored in a pocket/
handbag).
CAUTION
Danger of injuries due to unintended gate travel
Unintended gate travel may occur while teaching in the
radio system.
Pay attention that no persons or objects are in the
gate's travel range when teaching in the radio system.
ATTENTION
Functional disturbances caused by environmental
conditions
These conditions can impair function!
Protect the hand transmitter from the following conditions:
Direct sunlight (perm. ambient temperature: -20°C to •
+60°C)
Moisture•
Dust•
NOTES:
Perform a functional check after programming or •
extending the remote control system.
Only use original components for the initial start-up or for •
extending the remote control system.
Local conditions may affect the range of the radio •
system.
The hand transmitter works with a rolling code that changes
with each sending procedure. For this reason, it must be
taught in with the desired hand transmitter button on each
receiver that is to be controlled (see section 5.2.1 or the
receiver's operating instructions).
TR10L012-A RE / 05.2010 33