Operation Manual

6 Operation
WARNING
Danger of injury during gate travel
If people or objects are in the area
around the gate while the gate is in
motion, this can lead to injuries or
damage.
Children are not allowed to play
near the gate system.
Make sure that no persons or
objects are in the gate's travel
range.
Make sure that no persons or
objects are located between the
gate and the operator mechanics.
If the gate has only one safety
feature, only operate the gate
operator if you are within sight of
the gate's area of travel.
Monitor the gate travel until the gate
has reached the end-of-travel
position.
Only drive or pass through remote
control gate systems if the gate is in
the OPEN end-of-travel position!
Function tests
Check the function of the mechanical release
monthly.
To check the safety reversal, stop
the gate with both hands while it is
closing.
The gate system must stop and
initiate a safety reversal.
In the event of a failure of the safety reversal, a specialist
must be commissioned immediately for the inspection
and repair work.
Instructing users6.1
Instruct all persons who use the gate system on the
proper and safe use of the hinged gate operator.
Demonstrate and test the mechanical release as well as
the safety return.
Normal operation6.2
Press circuit board button
T, the external button or
activate impulse 1.
The gate moves in impulse sequence mode (OPEN/
STOP/CLOSE/STOP).
If impulse 2 is activated, leaf A (traffic leaf) will open if it
was previously closed (see Figures 5.3a/5.3b). If the leaf
offset is activated, leaf A can only move if leaf B is in the
CLOSE end-of-travel position.
Reversing during an opening run6.3
If the force limit is activated during an opening run, the
respective leaf will briefly reverse in the CLOSE direction, i.e.
the operator moves the gate in the opposite direction and
then stops. With a double-leaf gate, the uninvolved leaf
stops.
Reversing during a closing run6.4
If the force limit or photocell is activated during a closing run,
the respective leaf will briefly reverse in the OPEN direction
and then stop. If the photocell is activated, a long reversal
until the OPEN end-of-travel position will take place. During
impulse operation, the gate remains at a standstill and the
time starts again for automatic timed closing.
Behaviour during a power failure6.5
To be able to open or close the hinged gate during a power
failure, it must be disengaged from the operator (see
Figure 13.1). If the gate is also secured with an electric lock,
the lock must be unlocked with the appropriate key
beforehand.
Behaviour following a power failure6.6
Once the power supply has been restored, the gate must
be reengaged with the operator (see Figure 13.2)
A necessary reference run in the CLOSE direction is
automatically performed on the next command impulse
following a power failure. During this reference run the option
relay clocks and a connected warning lamp flashes slowly.
Disengaging without a power failure6.7
After reengaging the gate, the voltage supply must be
disconnected once so that a new reference run is
automatically performed in the CLOSE direction.
6.8 Factory reset
This can be used to reset the taught-in end-of-travel positions
and forces.
To perform a factory reset:
Set DIL switch 1. 4 to ON.
4 ON Set-up mode
4 OFF
Normal mode in press-and-release
operation
Immediately2. press circuit board button P briefly.
When the LED 3. RT flashes rapidly, quickly set
DIL switch 4 to OFF.
The control has now been reset to the factory settings.4.
The LED GN will flash slowly.
Operation, error and warning messages6.9
LED GN6.9.1
The green LED GN (see Figure 5.1) indicates the operating
conditions of the control:
Steady illumination
Normal state, all OPEN end-of-travel positions and forces
taught in.
Fast flashing
Force learning runs must be performed.
Slow flashing
End-of-travel positions must be taught in.
TR10L012-A RE / 05.2010 35