Operation Manual

LED RT6.9.2
The red LED RT (Figure 5.1) indicates:
Radio programming display
Flashing as described in section 5
Display of the button inputs:
Actuated = LED is on•
Not actuated = LED is off•
Error/diagnosis display
The LED RT helps to easily identify causes when operation
does not go according to plan.
LED RT Flashes 2x
Error/warning SE safety/protective device has
responded
Possible cause Safety/protective device has been •
actuated
Safety/protective device defective•
Remedy Check safety/protective device
LED RT Flashes 3x
Error/Warning Force limit in CLOSE direction
Possible cause Obstruction in gate area
Remedy Remove obstruction, check forces, and
increase, if necessary
LED RT Flashes 4x
Error/Warning Hold or static current circuit is open,
operator at a standstill
Possible cause Normally closed contact at terminal •
12/13 is open
Electric circuit interrupted•
Remedy Close contact•
Check electric circuit•
LED RT Flashes 5x
Error/warning Force limit in OPEN direction
Possible cause Obstruction in gate area
Remedy Remove obstruction, check forces, and
increase, if necessary
LED RT Flashes 6x
Error/warning System error
Possible cause Internal error
Remedy Restore the factory setting (see
section 6.8) and teach in the control again
or exchange, if necessary
Error acknowledgement6.10
Acknowledge the error after the cause of the error has been
eliminated:
Press the internal or external button or actuate the radio
hand transmitter.
The error is deleted and the gate travels in the
corresponding direction.
7 Inspection and Maintenance
The gate operator is maintenance-free.
In the interest of your own safety, we recommend having the
gate system inspected and maintained by a qualified person
in accordance with the manufacturer's specifications.
WARNING
Danger of injury due to unexpected gate travel
Unexpected gate travel can result during inspection and
maintenance work if the gate system is inadvertently
actuated by other persons.
Disconnect the mains plug when performing all work
on the gate system.
Safeguard the gate system against being switched on
again without authorisation.
An inspection or necessary repairs may only be carried out by
a qualified person. Contact your supplier for this purpose.
A visual inspection may be carried out by the operator.
Check all safety and protective functions
monthly.
Malfunctions and/or defects at hand must be rectified
immediately.
We would like to point out that any repairs not carried out
properly or with due professionalism shall render the
warranty null and void.
Optional Accessories8
Optional accessories are not included in the scope of delivery.
Loading of the operator by all electrical accessories:
max. 100 mA.
The following accessories are available:
External radio receivers•
External impulse buttons (e.g. key switch)•
Photocell•
Warning lamps/warning lights•
Electric lock for post locking•
Electric lock for floor locking•
Stop plate•
Set of base plates•
Dismantling and Disposal9
NOTE:
When disassembling, observe the applicable regulations
regarding occupational safety.
Have a specialist dismantle the gate operator in the reverse
order of these instructions and dispose of it properly.
Warranty Conditions10
Warranty
We shall be exempt from our warranty obligations and
product liability in the event that the customer carries out his
own structural alterations or undertakes improper installation
work or arranges for same to be carried out by others without
our prior approval and contrary to the fitting guidelines we
have provided. Furthermore, we will assume no responsibility
for the accidental or careless operation of the operator,
improper maintenance of the gate and its accessories, or for a
non-authorised method of fitting the gate. Batteries, light
bulbs and fuses are also not covered by the warranty.
36
TR10L012-A RE / 05.2010
ENGLISH