Operation Manual

Overview of DIL Switch Functions13
DIL 1 Single or double-leaf operation
ON Single-leaf operation
OFF Double-leaf operation
DIL 2 With/without leaf offset (only with double-leaf operation)
ON Without leaf offset: leaf A and B open and close simultaneously
OFF With leaf offset: leaf A opens before leaf B and leaf B closes before leaf A
DIL 3 Leaf selection/size of leaf offset
ON Leaf B/small leaf offset
OFF Leaf A/large leaf offset
DIL 4 Normal operation/setup operation
ON Set-up mode
OFF Normal mode in press-and-release operation
DIL 5 Safety device SE1 in the CLOSE direction (connection at terminal 73)
ON 2-wire photocell
OFF No safety equipment
DIL 6 DIL 7 Operator function Option relay function
ON ON Automatic timed closing, pre-warning time
for each leaf movement
Relay clocks rapidly during the pre-warning time,
normally during the travel phase and is OFF during
the hold-open phase
OFF ON No automatic timed closing, pre-warning
time for each leaf movement
Relay clocks rapidly during the pre-warning time,
normally during the travel phase
ON OFF Automatic timed closing, pre-warning time
only for automatic timed closing
Relay clocks rapidly during the pre-warning time,
normally during the travel phase and is OFF during
the hold-open phase
OFF OFF No special function Relay picks up in the CLOSE end-of-travel position
DIL 8 Normal/slow travel speed for all runs
ON Slow travel speed for all runs
OFF Normal travel speed for all runs
38
TR10L012-A RE / 05.2010
ENGLISH