Owner manual
MAN0577-03-en
Page 19 of 98
EO 09-0009
DeviceNet Modules
HE800DNM650 & HE800DNS600
3.3 Configuring a SmartStack DeviceNet Master with any DeviceNet Slave
Table 4 below describes the steps to configure a Horner Smartstack DeviceNet Master to any DeviceNet
Device (Slave).
Action Menu in the System Configurator
•
Create a new project
File > New > DeviceNet
•
Copy EDS file of the DeviceNet device (Slave), if the
device is not in the selection list.
File > Copy EDS
•
Choose Horner DeviceNet Master and provide MAC ID.
Insert > Master
•
Choose DeviceNet device and provide MAC ID address
Insert > Device
•
Assign the input and output modules (*1)
Mark the Device (left Mouse click), then
Settings > Device Configuration
•
Assign the offset addresses
•
Assign the Device Parameter data, if the Device needs
Parameter data
Mark the Device (left Mouse click), then
Settings > Device Configuration >
Parameter Data
•
Set the Bus parameter Mark the Master (left Mouse click), then
Settings > Bus Parameters
•
Set device assignment if no automatic assignment has
occurred
Mark the Master (left Mouse click), then
Settings > Device Assignment
•
Save project
File > Save
•
Download Mark the Master (left Mouse click), then
Online > Download
•
Live list Mark the Master (left Mouse click), then
Online > Live List
•
Start Debugger Mark the Master (left Mouse click), then
Online > Start Debug Mode
•
Device diagnostic Mark the Slave (left Mouse click), then
Online > Device Diagnostic
•
Stop Debugger
Online > Stop Debug Mode
•
Global Diagnostic Mark the Master (left Mouse click), then
Online > Global State Field
•
Transfer user data:
Write output, read input
Mark the Master (left Mouse click), then
Online > I/O Monitor
Table 4: Steps to Configure DNM650 with any DeviceNet Slave.
Note (*1): The Offset addresses assigned in the Slave configuration are always related to the Master.
3.4 Configuring a SmartStack DeviceNet Slave with any DeviceNet Master
Table 5 below describes the steps to configure a Horner DeviceNet Slave to any DeviceNet Master as it is
typical for many cases.
Action Menu in the System Configurator