Instruction Manual
CH.12 MAN0883-04-EN 
March 4, 2010  Page 64 of 135   #1037
View Status
The View Status Sub-Menu displays up to 17 System Settings. Only the Mode System Setting is 
editable. 
Model:  XL1yz  = Model number of this XL6/XL6e OCS unit 
    1yz indicates the installed I/O module;  00 = no I/O module 
OCS Mode:  Idle  = XL6/XL6e OCS is in Idle mode 
  DoIO  = XL6/XL6e OCS is in Do I/O mode 
  Run  = XL6/XL6e OCS is in Run mode 
Scan Rate(mS):  0.0  = XL6/XL6e OCS is not in Run mode 
  0.1 to 999.9  = Average number of mS for each ladder scan 
OCS Net Use %:  0.0 to 100.0  = CAN network bandwidth % used by this XL6/XL6e OCS node 
All Net Use %:  0.0 to 100.0  = CAN network bandwidth % used by all nodes 
Ladder Size:  x  = Number of bytes in application ladder program 
Config Size:  x  = Number of bytes in application I/O configuration 
Graphics Size:  x  = Number of bytes in application graphic screens 
String Size:  x  = Number of bytes in application string table 
Bitmap Size:  x  = Number of bytes in application bitmaps 
Text Tbl Size:  x  = Number of bytes in application text tables 
Font Tbl Size:  x  = Number of bytes in application font tables 
Protocol Size:  x  = Number of bytes in application downloaded protocols 
SMS File Size:  x  = Number of bytes in application SMS protocol configuration 
Firmware Rev:  xx.yy  = Current firmware version 
BIOS Rev:  x.yz  = Current CPLD (Complex Programmable Logic Device) version 
FPGA Rev:  x.y  = Current FPGA (Floating Point Gate Array) version 










