In some applications (such as jog buttons) where the operator is pushing a button for a period of time, the 
amount of slip while holding a button pressed may exceed the default sensitivity. To increase the amount 
of tolerable slip and prevent false releases of the button, the XL6/XL6e allows adjustment of the allowable 
slide up to 5x the default value. 
To enable the touch (slip) sensitivity, first an OCS data register must be allocated through the Graphics 
editor Configuration menu for Display Settings. Once a Touch Sensitivity register is assigned, that 
register may be modified [range = 1(Low) to 5 (High)] to the desired slide amount. If a value outside the 
valid range is entered in the touch sensitivity register, it is ignored and the last valid value is used. 
 13.8  Alarms 
Alarm presentation to the operator is highly configurable and beyond the scope of this document to 
describe fully. For more information refer to the graphics editor help file. This section presents a typical 
configuration thereby providing an introductory description on what the operator should expect. 
The alarm object is generally used to enunciate alarms to the operator. While the display characteristics 
of this object is configurable, it is generally displayed as a button that changes colors to indicate the 
highest state of the alarm(s) in the alarm group it is monitoring. The following indicates the priority of the 
alarm states and the default colors associated with these states. 
•  Highest  (Red)  - Unacknowledged Alarms Exist 
•   -  (Yellow)  - Acknowledged Alarms Exist 
•  Lowest  (Green)  - No Alarms Exist 
Figure 13.3 – Alarm Object 
To view, acknowledge and/or clear alarms, the operator must access the alarm viewer. This is 
accomplished by touching an (enabled) alarm object. When accessed, the alarm viewer is displayed as 
pop-up alarm viewer dialog similar to that shown in Figure 13.6. 
Figure 13.4 – Alarm Viewer 