Service Manual

27
B. Optional Drain Pump HS-5061
If the optional drain pump (HS-5061) is installed, test its operation at least once a year
as outlined below. Note that the pump has power even when the control switch is in the
"OFF" position.
1) Move the control switch to the "OFF" position, then unplug the appliance from the
electrical outlet. WARNING! To reduce the risk of electric shock, do not touch the
control switch or plug with damp hands.
2) Remove all ice from the ice storage bin.
3) Plug the appliance back in.
4) Slowly pour 24 to 30 oz. (710 to 890 ml) of water over the ice storage bin drain hole in
the ice storage bin.
5) If water pumps out properly and the drain pump then de-energizes, proceed to step 6.
If water does not pump out, conrm 115VAC to drain pump, replace as needed.
6) Move the control switch to the "ICE" position.
7) Pour another 24 to 30 oz. (710 to 890 ml) of water into the ice storage bin, then
completely restrict the discharge hose while the drain pump is operating. See Fig.2.
Pour more water into the ice storage bin until the appliance turns off. The drain pump
will continue to operate. Check for leaks.
8) Remove the discharge hose restriction and allow the water to be pumped out normally.
Power to the appliance will be restored when the water in the drain pump returns to a
normal level.
9) If the appliance fails to turn off with the discharge hose restricted or the drain pump fails
to pump out the water, replace the drain pump.
Fig. 2
Discharge Hose