Service Manual

30
VIII. Technical Information
We reserve the right to make changes in specications and design without prior notice.
A. Specication and Performance Data
Pressure data is recorded at 5 min. into freezing cycle. The data not in bold should be
used for reference only.
1. AM-50BAJ(-DS)
Specification Sheet
AC SUPPLY VOLTAGE 115-120/60/1
AMPERAGE 3.8 A
MINIMUM CIRCUIT AMPACITY 15 A
MAXIMUM FUSE SIZE 15 A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 244 (17.0) 222 (10.4)
WATER gal./24HR (gal./100 lbs.) 24.0 (71.0) 44.0 (85.0)
ICE PRODUCTION PER CYCLE 0.6 lbs. (0.3 kg) 24pcs.
APPROXIMATE STORAGE CAPACITY 27 lbs. (12.5 kg) [Bin Control Setting 22 lbs. (10.0 kg)]
BIN CONTROL SYSTEM Thermostat
REFRIGERANT CHARGE R134a, 0 lb. 4.2 oz. (120g)
Performance Data Sheet
70/21 51 23
46 21 43 20
lbs./day kg./day
100/38 40 18 34 16 29 13
70/21
80/27
90/32
watts 100/38
70/21 44 0.17
38 0.14 33 0.12
80/27 39 0.15 31 0.12 27 0.10
90/32 38 0.14 24 0.09 20 0.08
gal./day m
3
/day
100/38 31 0.12 23 0.09 16 0.06
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 140 9.8
152 10.7 175 12.3
80/27 149 10.5 167 11.8 194 13.7
90/32 152 10.7 180 12.7 206 14.5
PSIG kg/cm
2
G
100/38 159 11.2 186 13.1 230 16.2
70/21 15 1.1 16 1.2 19 1.3
80/27 16 1.1 18 1.3 21 1.5
90/32 16 1.2 20 1.4 23 1.6
PSIG kg/cm
2
G
100/38 17 1.2 21 1.4 25 1.8
1,900 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR 800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
3 2 2.1
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
3.1
22
32 2
3 2.4 2
26
19 24 29
25 29 33
237 246 255
A
PPROXIMATE WATER CONSUMPTION
PER 24 HR.
FREEZING CYCLE TIME
16 19 23
18 21
APPROXIMATE ELECTRIC
CONSUMPTION
222 228 235
227 237 242
228 244 250
APPROXIMATE ICE
PRODUCTION PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10 70/21 90/32
ENG.F-011.1.0205