VII. Technical Information
A. Electrical and Refrigerant Data
Model (includes drawer models)
AC Supply
Voltage Amperes
Design
Pressure
(PSIG)
Refrigerant
(oz.)
HIGH LOW 134a
CRMR27 Undercounter, Worktop, and Prep Table 115/60/1 2.6 290 120 5.6
CRMF27 Undercounter and Worktop 115/60/1 3.4 310 120 5.0
CRMR36 Undercounter, Worktop, Prep Table, and Mega
To p
115/60/1 2.9 290 120 5.6
CRMR48 Undercounter and Worktop 115/60/1 2.6 240 120 6.5
CRMR48 Prep Table and Mega Top 115/60/1 2.6 290 120 6.5
CRMF48 Undercounter and Worktop F-7 and Earlier
115/60/1
6 360 140 9.2
CRMF48 Undercounter and Worktop G05 and Later 4.7 360 140 7
CRMR60 Undercounter and Worktop 115/60/1 4.2 290 120 8
CRMR60 Prep Table and Mega Top F-7 and Earlier
115/60/1 6 360 140
10.3
CRMR60 Prep Table and Mega Top F-8 and Later and
Models Converted with SP-5227 Kit
9.5
CRMF60 Undercounter and Worktop F-7 and Earlier
115/60/1
6 360 140 10.6
CRMF60 Undercounter and Worktop G-5 and Later 9.5 360 140 9.5
CRMR72 Undercounter and Worktop 115/60/1 4.2 290 120 8
CRMR72 Prep Table and Mega Top F-7 and Earlier
115/60/1 6 360 140
12
CRMR72 Prep Table and Mega Top F-8 and Later and
Models Converted with SP-5227 Kit
10.4
See the nameplate for electrical and refrigeration specications. The nameplate is located
inside the cabinet.
We reserve the right to make changes in specications and design without prior notice.