Instruction Manual

23
1. Icemaker
Icemaker Water
Supply Inlet
Minimum Icemaker
Water Supply Line Size
Icemaker Drain
Outlet
Minimum Icemaker
Drain Line Size
1/2" Female Pipe
Thread (FPT)
1/4" Nominal ID
Copper Water Tubing or
Equivalent
3/4" Female Pipe
Thread (FPT)
3/4" NominalID
Hard Pipe or
Equivalent
An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be
pulled out for service.
Fig. 4
Icemaker
Icemaker
Water Supply
Inlet
1/2" FPT
Bin Drain Outlet
3/4" FPT
2-inch (5-cm) air gap
Floor
Drain
Icemaker
Drain Outlet
3/4" FPT
Ice
Storage
Bin
Model Shown:
F-801MAJ
Vent Tube
Minimum 3/4" Nominal ID
Hard Pipe or Equivalent
Air-Cooled, Remote, and Low-Side Models
Drain Valve
Shut-Off Valve
Separate piping to approved
drain. Leave a 2-inch (5-cm)
vertical air gap between the
end of each pipe and the
drain.
Be sure there is sufficient
extra water supply line and
drain line for the appliance
to be pulled out for service.
Minimum 1/4" Nominal ID Copper
Water Tubing or Equivalent