Instruction Manual
Table Of Contents
- Important Safety Information
- I. Specifications
- A. Electrical and Refrigerant Data
- B. Dimensions/Connections
- 1. Air-Cooled Models (MAJ(-C))
- 2. Water-Cooled Models (MWJ(-C))
- 3. Remote Models (MRJ/3(-C))
- 4. Low Side, Parallel Rack System Models (MLJ)
- 5. Remote Condenser Unit URC-5F (use with F-1002MRJ(-C), FD-650MRJ-C, FD-1002MRJ-C)
- 6. Remote Condenser Unit URC-14F (use with F-1501MRJ(-C))
- 7. Remote Condenser Unit URC-22F (use with F-2001MRJ/3(-C))
- II. Installation and Operating Instructions
- A. Location
- B. Checks Before Installation
- C. How to Remove Panels
- D. Dispenser Unit/Ice Storage Bin and Icemaker Setup
- E. Electrical Connection
- F. Water Supply and Drain Connections
- G. Remote Condenser Unit Installation
- H. Parallel Rack System Connection
- I. Final Checklist
- J. Startup
- K. Bin Control Check
- L. Alarm Safeties
- III. Maintenance
- IV. Preparing the Appliance for Periods of Non-Use
- V. Disposal
38
J. Startup
WARNING
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
NOTICE
• If the appliance is turned off, wait for at least 3 minutes before restarting the
appliance to prevent damage to the compressor.
• At startup, conrm that all internal and external connections are free of leaks.
Additional Notice for Remote Models
• The appliance must have power for a minimum of 4hours prior to startup to
prevent compressor damage.
1) Open the water supply line shut-off valve(s).
2) Remove the front panel.
3) Move the control switch on the control box to the "ICE" position, then move the power
switch to the "ON" position.
4) Replace the front panel in its correct position.
5) Turn on the power supply to start the automatic icemaking process.
6) Once the unit starts to produce ice, allow it to run for another 30 minutes. On
water-cooled models, conrm proper condenser drain outlet/return outlet temperature
as outlined in "II.F.2. Water-Cooled Condenser." On low-side rack system models, if not
utilizing R-404A, conrm proper EPR valve setting as outlined in "II.H.1. Line Set Size
and Rack System Requirements."
7) Turn off the power supply, then remove the front panel.
8) Move the control switch to the "DRAIN" position, then replace the front panel in its
correct position. Turn on the power supply and allow the water system to drain for
5 minutes.
9) Remove the front panel.
10) Move the power switch to the "OFF" position, then turn off the power supply.
11) Pour warm water into the dispenser unit/ice storage bin and melt any remaining ice.
Clean the dispenser unit/ice storage bin liner using a neutral cleaner. Rinse thoroughly
after cleaning.
12) Conrm bin control operation. See "II.K. Bin Control Check."