Instruction Manual

46
10) In bad or severe water conditions, clean the oat switch as described below. Otherwise,
continue to step 11.
a. Remove the oat switch from the reservoir cover.
b. Wipe down the oat switch with the cleaning solution.
c. Rinse the oat switch thoroughly with clean water.
d. Replace the oat switch in its correct position.
11) Wipe down the infrared sensor lens, (located on the bottom of the icemaker) with the
cleaning solution. Next, rinse the cleaning solution off of the infrared sensor lens with a
clean, damp cloth.
12) Move the control switch to the "ICE" position, then move the power switch to the "ON"
position. Replace the panels in their correct positions. Turn on the power supply and
make ice using the solution until the icemaker stops making ice.
13) Turn off the power supply, then remove the front panel. Move the control switch to the
"DRAIN" position, then replace the front panel in its correct position.
14) Turn on the power supply and allow the water system to drain completely.
15) Turn off the power supply, then remove the front panel. Move the control switch to the
"ICE" position, then replace the front panel in its correct position.
16) Open the icemaker water supply line shut-off valve, then turn on the power supply to
supply water to the reservoir.
17) After the gear motor starts, turn off the power supply. Remove the front panel, then move
the control switch to the "DRAIN" position. Replace the front panel in its correct position.
18) Turn on the power supply and allow the water system to drain completely.
Note: If you do not sanitize the unit, go to step 14 in "III.B.5. Sanitizing
Procedure - Final."
19) Turn off the power supply, then close the icemaker water supply line shut-off valve.
3. Sanitizing Solution
Dilute 2.5 . oz. (74 ml or 5 tbs) of a 5.25% sodium hypochlorite solution (chlorine
bleach) with 5 gal. (19 l) of warm water. This is a minimum amount. Make more solution
if necessary. IMPORTANT! For safety and maximum effectiveness, use the solution
immediately after dilution.
4. Sanitizing Procedure - Initial
1) Make sure the power supply is off and the icemaker water supply line shut-off valve
is closed. Remove the front and top panels, then move the power switch to the "OFF"
position.
2) Remove the spout-to-chute strap (includes drip guide on F-1501 and larger) connecting
the spout to the chute assembly, then remove the spout. Remove the evaporator
packing (F-450) or rubber O-ring and nylon ring (FD-650 and larger) at the top of the
cylinder and also remove the spout-to-chute bracket (F/FD-1002 and smaller) and
spout-to-chute packing between the spout and chute.
3) Pour the sanitizing solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to run through the overow hose on the
reservoir.