Instruction Manual
Table Of Contents
- Important Safety Information
- I. Specifications
- A. Electrical and Refrigerant Data
- B. Dimensions/Connections
- 1. Air-Cooled Models (MAJ(-C))
- 2. Water-Cooled Models (MWJ(-C))
- 3. Remote Models (MRJ/3(-C))
- 4. Low Side, Parallel Rack System Models (MLJ)
- 5. Remote Condenser Unit URC-5F (use with F-1002MRJ(-C), FD-650MRJ-C, FD-1002MRJ-C)
- 6. Remote Condenser Unit URC-14F (use with F-1501MRJ(-C))
- 7. Remote Condenser Unit URC-22F (use with F-2001MRJ/3(-C))
- II. Installation and Operating Instructions
- A. Location
- B. Checks Before Installation
- C. How to Remove Panels
- D. Dispenser Unit/Ice Storage Bin and Icemaker Setup
- E. Electrical Connection
- F. Water Supply and Drain Connections
- G. Remote Condenser Unit Installation
- H. Parallel Rack System Connection
- I. Final Checklist
- J. Startup
- K. Bin Control Check
- L. Alarm Safeties
- III. Maintenance
- IV. Preparing the Appliance for Periods of Non-Use
- V. Disposal
50
3. On water-cooled models, remove the water from the water-cooled condenser:
1) Make sure the power supply is off, then remove the front panel and right side panel.
2) Close the condenser water supply line shut-off valve. If connected to a closed loop
system, also close the condenser return line shut-off valve.
3) Open the condenser water supply line drain valve. If connected to a closed loop system,
also open the condenser return line drain valve.
4) Attach a compressed air or carbon dioxide supply to the condenser water supply line
drain valve.
5) Open the water regulating valve by using a screwdriver to pry up on the spring retainer
underneath the spring. While holding the valve open, blow out the condenser using the
compressed air or carbon dioxide supply until water stops coming out.
6) Close the drain valve(s).
7) Replace the right side panel and front panel in their correct positions.