Instruction Manual

8
3. F-1002M_J(-C)
Single Phase
Model Number F-1002MAJ(-C) F-1002MWJ(-C) F-1002MRJ(-C) F-1002MLJ(-C)
AC Supply Voltage 115/60/1 115/60/1 115/60/1 115/60/1
Compressor 115V 11.2RLA
93LRA
115V 10.7RLA
93LRA
115V 11.2RLA
93LRA
– – –
Gear Motor 115V 3.0FLA 200W 115V 3.0FLA 200W 115V 3.0FLA 200W 115V 3.0FLA 200W
Fan Motor 115V 1.0FLA
1/15HP
– – – 115V 3A MAX
(Fan in URC)
– – –
Other 115V 0.03A 115V 0.03A 115V 0.53A 115V 0.53A
Maximum Fuse Size 20 AMPS 20 AMPS 20 AMPS 15 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS 20 AMPS 20 AMPS 15 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS 20 AMPS 20 AMPS 15 AMPS
Minimum Circuit
Ampacity
20 AMPS 20 AMPS 20 AMPS 15 AMPS
Design Pressure HI-467PSI
LO-250PSI
HI-427PSI
LO-250PSI
HI-467PSI
LO-250PSI
HI-467PSI
LO-250PSI
Refrigerant 404A 2 LB. 4 OZ. 404A 12.3 OZ. 404A
Total Refrigerant
Charge with
Hoshizaki Remote
Condenser Unit
URC-5F: 4LB. 1.2
OZ.
Use only with 404A,
407A, or 407F
4. F-1501M_J(-C)
Single Phase
Model Number F-1501MAJ(-C) F-1501MWJ(-C) F-1501MRJ(-C)
AC Supply Voltage 208-230/60/1 (3 wire with
neutral)
208-230/60/1 (3 wire with
neutral)
208-230/60/1 (3 wire with
neutral)
Compressor 208-230V 9.3RLA 56LRA 208-230V 9.3RLA 56LRA 208-230V 9.3RLA 56LRA
Gear Motor 115V 5.6FLA 400W 115V 5.6FLA 400W 115V 5.6FLA 400W
Fan Motor 115V 1.0FLA 1/15HP Cabinet: 115V 0.51FLA 8W Cabinet: 115V 0.51FLA 8W
Remote: 115V 3A MAX
Other 115V 0.03A 115V 0.03A 115V 0.03A
Maximum Fuse Size 20 AMPS 20 AMPS 20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS 20 AMPS 20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS 20 AMPS 20 AMPS
Minimum Circuit
Ampacity
20 AMPS 20 AMPS 20 AMPS
Design Pressure HI-467PSI LO-250PSI HI-427PSI LO-250PSI HI-467PSI LO-250PSI
Refrigerant 404A 2 LB. 5 OZ. 404A 1 LB 4.5 OZ. 404A
Total Refrigerant Charge
with Hoshizaki Remote
Condenser Unit URC-14F:
9LB. 9 OZ.