Instruction Manual

9
5. F-2001M_J(-C)
Single Phase
Model Number F-2001MWJ(-C) F-2001MRJ(-C) F-2001MLJ
AC Supply Voltage 208-230/60/1 208-230/60/1 115/60/1
Compressor 240V 10.8RLA 96LRA 240V 10.8RLA 96LRA – – –
Gear Motor 120V 5.6 FLA 400W 120V 5.6 FLA 400W 120V 5.6 FLA 400W
Cabinet Fan Motor 115V 0.51 FLA 8W 115V 0.51 FLA 8W 115 0.51 FLA 8W
Remote Fan Motor – – – 120V 3A MAX
Other 120V 0.03A 120V 0.03A 120V 0.3A
Maximum Fuse Size 30 AMPS 30 AMPS 15 AMPS
Max. HACR Breaker
(USA Only)
30 AMPS 30 AMPS 15 AMPS
Max. Circuit Breaker
(Canada Only)
30 AMPS 30 AMPS 15 AMPS
Minimum Circuit
Ampacity
30 AMPS 30 AMPS 15 AMPS
Design Pressure HI-467PSI
LO-290PSI
HI-467PSI
LO-290PSI
HI-467PSI
LO-290PSI
Refrigerant 404A 2 LB. 404A
Total Refrigerant Charge
with Hoshizaki Remote
Condenser Unit
URC-22F: 15LB. 14 OZ.
Use only with 404A,
407A, or 407F
6. F-2001MRJ3
Three Phase
Model Number F-2001MRJ3
AC Supply Voltage 208-230/60/3
Compressor 240V 9.0RLA 75LRA
Gear Motor 120V 5.6 FLA 400W
Cabinet Fan Motor 115V 0.51 FLA 8W
Remote Fan Motor 120V 3A MAX
Other 120V 0.03A
Maximum Fuse Size 20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS
Minimum Circuit
Ampacity
20 AMPS
Design Pressure HI-467PSI
LO-290PSI
Refrigerant 404A
Total Refrigerant Charge
with Hoshizaki Remote
Condenser Unit
URC-22F: 15LB. 14 OZ.