Instruction Manual

9
1.5 Installation and assembly
This appliance is intended for indoor use only. Be sure the location chosen has a floor
strong enough to support the total weight of the unit and contents. For the most efficient
operation, be sure to provide good air circulation inside and outside of the unit.
INSIDE CABINET
The first cleaning must be made when you unpack the unit and before switching it on.
Clean it with water and a mild detergent. When it is clean and dry, insert the
accessories in the appropriate places, for the best use of the user.
OUTSIDE CABINET
Be sure the unit has good air circulation around it. Avoid hot corners and locations near
stoves and ovens. It is recommended the unit be installed no closer than 2” from any
wall. Place in a clean area to avoid clogging the condenser, which can cause low
performance and failures.
The unit should not be installed in ambient temperatures higher than 100°F. If the
relative humidity is higher than 60%, condensation may form around the door
frame. This is not a malfunctioning of the unit.
1.6 Connections
Refer to the amperage data on the nameplate and your local code or the National
Electrical Code to be sure unit is connected to the proper power source. Verify correct
incoming voltage according to the nameplate information.
A protected circuit of the correct voltage and amperage must be run for connection of
the power cord. Unit must be grounded and connected in accordance with NEC Article
422 Appliances.