C. Air Filter
A plastic mesh air filter removes dirt or dust from the air,
and keeps the condenser from getting clogged. If the fi lter
gets clogged, the showcase’s performance will be reduced.
Check the fi lter at least twice a month. When clogged, use
warm water and a neutral cleaner to wash the fi lter.
1) Hold the tabs located at the bottom of the louver, and lift
them up to release the louver from the body.
2) Pull the louver toward you.
3) Pull the louver downward.
4) Grasp the frame of the air fi lter, and pull it toward you.
5) Clean the air fi lter.
6) Refi t the air fi lter and louver in the reverse order of the
removal procedure.
D. Condenser
Check the condenser once a year, and clean if required by using a brush or vacuum
cleaner. More frequent cleaning may be required depending on the location of the
showcase.
E. Checking Ground Fault Circuit Interrupter
Push the test button at least once a month, and simulate a ground fault on the load circuit.
Fig. 6
Louver
4
Air Filter