2. Bin Control Installation
NOTICE
Before operating the icemaker, the bin control must be installed. Failure to properly
install the bin control could result in ice backup and icemaker damage.
1) Install the bin control thermostat assembly as follows. See Fig. 3.
a. Remove the bin control thermostat assembly from the shipping hook.
b. Remove the 2 thumbscrews below the bin control thermostat assembly.
c. Lower the bin control thermostat assembly through the hole located in the bottom of
the icemaker. Secure the bin control thermostat assembly with the lower hook and
the 2 thumbscrews removed in the previous step.
d. Insert the plug into the receptacle on the assembly until it locks into place.
IMPORTANT! The plug must be inserted into the receptacle for the icemaker to
operate.
2) Replace the panels in their correct positions.