Service Manual

12
2. Freezer
3. Cool Down Restart
Legend:
Comp-compressor
ConFM-condenser fan motor
CTh-cabinet thermistor
DH-defrost heater
DrH-drain heater
DTh-defrost thermistor
EvapFM-evaporator fan motor
MH-mullion heater
PH-perimeter heater
TXVH-thermostatic expansion
valve heater
1. Startup/Cool Down
2. Cool Down Achieved
Comp energized
ConFM energized
EvapFM energized
(30-sec. delay
after Comp
energized)
CTh in control
Slight
Delay at
Startup
CTh cools to
3°F (1.7°C)
below setpoint.
Factory default
-2°F (-19°C)
CTh warms
to 3°F (1.7°C)
above setpoint
4. Defrost
Comp de-energized
ConFM de-energized
EvapFM de-energized
(60-sec. delay
after Comp
de-energized)
5. Defrost Termination
DH de-energized
*After Drip Time Delay:
Comp energized
ConFM energized
EvapFM energized
*(Once DTh reaches 15°F (-9°C)
or 4-min. EvapFM terminates,
whichever comes rst)
DTh warms to 77°F (25°C)
or 1-hr maximum defrost
timer terminates
Note: *Delays
a) EvapFM delays energizing if DTh above 32°F (0°C).
b) EvapFM de-energizes when door is opened on -FS models and when upper door is
opened on -HS models.
c) 2-min. minimum Comp on timer starts when Comp energizes.
d) 2-min. minimum Comp off timer starts when Comp de-energizes.
e) 5-min. minimum defrost time.
f) 1-hr. maximum defrost time.
g) "dEF" displayed during defrost.
h) 3-min. Comp/ConFM delay timer starts when defrost termination temperature is met.
i) 4-minute EvapFM delay timer starts when Comp/ConFM delay timer terminates
j) 15-minute temperature delay timer starts when EvapFM energizes
Power on
DH energized
Comp de-energized
ConFM de-energized
EvapFM de-energized
2-min. Comp off
timer starts
2-min. Comp on
timer starts
5-hr. cumulative Comp run or
4-hr. continuous run defrost
timer terminates
Freezer Sequence Flow Chart
DrH energized
MH energized
PH energized
TXVH energized
(F2A Models)
5-min.
minimum
defrost
DTh in
control
5-hr. cumulative Comp run or
4-hr. continuous run defrost
timer starts