B. Component Service Information
DANGER
• Component parts shall be replaced with like components.
• Les pièces des composants doivent être remplacées par des pièces et accessoires
équivalents.
NOTICE
When replacing a component listed below, see the notes to help ensure proper
operation.
Component Notes
Compressor Install a new start relay and compressor external protector. WARNING! To reduce the
risk of electric shock, be sure to reconnect the compressor's ground wire.
Thermostatic
Expansion Valve
Attach the thermostatic expansion valve bulb to the suction line in the same location as
the previous bulb.
The bulb should be between the 10 and 2 o'clock positions on the tube.
• Secure the bulb with the clamp and holder.
Defrost Thermis-
tor
After working with or around the defrost thermistor on a freezer, make sure the defrost
thermistor wire is not touching the defrost heater.
C. Door Reversal
The appliance is provided with a cabinet design which, after being delivered to the
installation location, permits changing of the door swing from left to right or right to left.
To change the door swing, See Instruction Manual "I.F. Door Reversal".
NOTICE! Improper installation may result in the doors not closing completely and/
or the gaskets not sealing correctly. For further details, contact your local Hoshizaki
distributor or Hoshizaki Technical Support at 1-800-233-1940.