Service Manual

29
B. Temperature
The temperature default scale is °F, but it can be changed to read °C. To change,
see "III.B.3. Changing the Temperature Display Scale (°F or °C)" below.
1. Default Settings
a) Temperature Setpoint:
Model Auxiliary Code Temperature Setpoint
Refrigerator All 38°F (3°C)
Freezer All -2°F (-19°C)
b) Temperature Display Scale: °F.
2. Temperature Setpoint
The temperature setpoint is the value for the average cabinet temperature. The
temperature differential for the compressor to turn on and off is ±3°F (±1.7°C) of the
temperature setpoint. For example, for a refrigerator temperature setpoint of 36°F (2°C),
the compressor comes on at 41°F (5°C), and the compressor goes off at 31°F (-1°C).
If necessary, adjust the temperature setpoint as follows:
1) To change the temperature setpoint, press and hold the up button briey and then
release. The current temperature setpoint appears.
2) Press the up or down button until the desired value is displayed. After a few seconds,
the display returns to the current cabinet temperature and the temperature setpoint is
saved. NOTICE! Do not adjust the temperature setpoint more than 2°F (1°C) at a
time. Allow the temperature to stabilize for a minimum of 8hours before making
further temperature setpoint adjustments.
• For refrigerators, the temperature setpoint is adjustable between 31°F and 52°F
(-0.5°C and 11°C). The factory default is 38°F (3°C).
• For freezers, the temperature setpoint is adjustable between -10°F and +12°F (-24°C
and -11°C). The factory default is -2°F (-19°C).
3. Changing the Temperature Display Scale (°F or °C)
To change the temperature display scale, follow the steps below. The factory default is °F.
1) Press and hold both the up and down buttons for 5 seconds. "PAS" appears briey in
the display, then "000" appears.
2) Press the up button to change the display to "001".
3) Press the standby button. "
EHE
" appears in the display. Press the up or down button
until "diS" is displayed.
4) Press the standby button. "CFu" appears in the display. Press the standby button again.
The current temperature display scale setting appears. Press the up or down button to
change the temperature display scale.
5) Press the standby button to save the setting. Wait 1 minute or press the manual defrost
button twice to return to the temperature display.