Refrigerator User Manual

4
* Allow at least 6” (15 cm) clearance around the merchandiser for proper air circulation
and
ease of maintenance and/or service should they be required.
2) Level the merchandiser in both the left-to-right and front-to-rear directions. Metal shims
should be added under the feet to level the system.
3. ELECTRICAL CONNECTIONS
WARNING
This refrigerated merchandiser requires a ground that meets the national and
local
electrical code requirements. To prevent possible severe electrical shock
to
individuals or extensive damage to the equipment, install a proper grounding
wire
to the merchandiser.
* This merchandiser must be plugged into the separated power receptacle which has enough
ca
pacity. The maximum allowable voltage variation should not exceed ± 10 percent of the
namepla
te rating. See the Nameplate.
* Usually an electrical permit and services of a licensed electrician are required.
Note
: This merchandiser is equipped with a Ground Fault Circuit Interrupter (GFCI). Locate
the
GFCI on the upper middle part of the rear, next to the Rocker Switch for Fluorescent
Lamp
.
4. DRAIN CONNECTIONS
No plumbing is required as a slide-out
Cassette Tank is provided. Attach the
Cass
ette Tank to the bottom of the
merchandise
r.
Drain Hose
Bracket
Drain
Hole
Rear
Front
Tank Drain Hole
Cassette
Tank
(Capacity: approx. 0.4 gal)