Parts List

19
RM-26
PROBLEM POSSIBLE CAUSE SOLUTION
COMPRESSOR NO VOLTAGE IN THE ELECTRICAL USE A VOLTMETER TO
WILL NOT START SOCKET CHECK THE VOLTAGE
THE ELECTRICAL CONDUCTOR USE AN OHMMETER,
OR WIRES MAY BE CUT TO CHECK FOR CONTINUITY
DEFECTIVE ELECTRICAL REPLACE DEFECTIVE
COMPONENTS SUCH AS: COMPONENTS
THERMOSTAT, RELAY, THERMAL
PROTECTOR, ETC.
COMPRESSOR MOTOR HAS A MEASURE THE OHMIC
WINDING OPEN OR SHORTED RESISTANCE OF THE MAIN AND
AUXILIARY WINDINGS USING AN
OHMMETER. COMPARE THEM WITH
THE CORRECT VALUES
DIRTY CONDENSER, LACK OF AIR CLEAN CONDENSER AND
FLOW ALLOW FOR AIR CIRCULATION
LOW VOLTAGE USE A VOLTAGE REGULATOR IF
THE VOLTAGE IS LOWER THAN
100 VOLTS
COMPRESSOR IS STUCK CHANGE THE COMPRESSOR
THE TEMPERATURE THERMOSTAT DOES NOT DISCONNECT CHECK THE INSTALLATION OF THE
IS TOO COLD THE CONDENSING UNIT THERMOSTAT. IF THE PROBLEM
PERSISTS, CHANGE THE THERMOSTAT
THERMOSTAT’S AMBIENT SENSOR IS CORRECTLY FASTEN THE
LOOSE OR INSTALLED IMPROPERLY THERMOSTAT’S AMBIENT SENSOR
THE TEMPERATURE CONDENSER IS DIRTY; LACK OF AIR CLEAN THE CONDENSER AND
IS NOT COLD ENOUGH FLOW ALLOW FOR AIR CIRCULATION
TROUBLESHOOTING
Possible causes and solutions