Parts List

20
RM-26
PROBLEM POSSIBLE CAUSE SOLUTION
THE TEMPERATURE THE REFRIGERATOR HAS BEEN THE UNIT MUST NOT BE NEAR
IS NOT COLD ENOUGH PLACED AT AN INADEQUATE STOVES, WALLS THAT ARE
LOCATION EXPOSED TO THE SUN, OR PLACES
THAT LACK SUFFICIENT AIR FLOW
THE REFRIGERATOR HAS BEEN USED THE SHELVES MUST NEVER BE
IMPROPERLY COVERED WITH ANY TYPE OF PLASTIC OR
OTHER MATERIAL THAT WILL BLOCK THE
CIRCULATION OF COLD AIR WITHIN THE
REFRIGERATOR
THE REFRIGERATOR HAS BEEN CHECK TO SEE IF CONDENSATION
OVERCHARGED WITH THE OR ICE CRYSTALS HAVE FORMED
REFRIGERANT GAS ON THE SUCTION LINE. IF SO, CHARGE
WITH THE CORRECT AMOUNT OF GAS
THE REFRIGERANT GAS IS LEAKING FIND THE LOCATION WHERE THE GAS IS
LEAKING IN ORDER TO SEAL IT OR
REPLACE THE DEFECTIVE COMPONENT.
CHANGE THE DRIER. PERFORM A GOOD
VACUUM AND RECHARGE THE UNIT
THE EVAPORATOR AND/OR CHECK THE ELECTRICAL CONNECTIONS
CONDENSER FANS AREN’T WORKING AND MAKE SURE THAT THE FAN BLADE
ISN’T STUCK. REPLACE THE FAN MOTOR
IF IT DOESN’T WORK
LOW VOLTAGE USE A VOLTAGE REGULATOR IF THE
VOLTAGE IS LOWER THAN 100 VOLTS
ELECTRICAL SHOCKS WIRES OR ELECTRICAL COMPONENTS CHECK FOR APPROPRIATE INSULATION ON
ARE IN DIRECT CONTACT WITH THE CONNECTIONS OF EACH ELECTRICAL
METALLIC PARTS COMPONENT
NOISE THE REFRIGERATOR IS NOT CHECK IF THE NOISE GOES
PROPERLY LEVELED AWAY AFTER YOU LEVEL THE
REFRIGERATOR
THE CONDENSER IS NOT FASTENED WHILE THE COMPRESSOR IS WORKING,
CORRECTLY. COPPER TUBINGS CHECK TO SEE IF METAL PARTS ARE IN
ARE IN CONTACT WITH METAL CONTACT WITH ONE ANOTHER AND/OR
IF THE SCREWS THAT FASTEN THE
CONDENSER ARE TIGHTENED
THE EVAPORATOR AND/OR CHECK IF THE FANS ARE SECURELY
CONDENSER FANS ARE LOOSE FASTENED. ALSO, CHECK IF THE
FAN BLADES ARE LOOSE, BROKEN
OR CROOKED. IF SO, CHANGE THE
FAULTY BLADE
COMPRESSOR HAS AN INTERNAL IF THE NOISE PERSISTS AFTER
NOISE ALL OTHER MEASURES HAVE BEEN
TAKEN, IT MAY BE ORIGINATING FROM
THE COMPRESSOR