PROBLEM POSSIBLE CAUSE SOLUTION
EXTREME CONDENSATION THERMOSTAT’S AMBIENT SENSOR IS CORRECTLY FASTEN THE
INSIDE THE REFRIGERATOR LOOSE OR INSTALLED IMPROPERLY THERMOSTAT’S AMBIENT SENSOR
THE OUTSIDE ENVIRONMENT’S THIS TYPE OF OCCURRENCE IS
RELATIVE HUMIDITY IS VERY HIGH CAUSED BY LOCAL CLIMATIC
(OVER 75%) CONDITIONS AND NOT BY THE
REFRIGERATED UNIT
THE REFRIGERATOR DOOR WON’T CHECK THE DOOR AND/OR THE
SHUT COMPLETELY MAGNETIC GASKET. ADJUST THE
DOOR HINGES IF NEEDED; REPLACE
THE GASKET IF BROKEN
THE REFRIGERATOR HAS BEEN THE UNIT MUST NOT BE NEAR
PLACED AT AN INADEQUATE SOURCES THAT PRODUCE
LOCATION TOO MUCH HEAT
NO ILLUMINATION THE LIGHT SWITCH IS IN “OFF” PRESS THE LIGHT SWITCH
POSITION TO THE “ON” POSITION
FALSE CONTACT ON THE LIGHT INSPECT ALL CONNECTIONS
SWITCH OR LED
LIGHT SWITCH OR LED ARE DAMAGED REPLACE THE DAMAGED COMPONENT
THE THERMOSTAT IS SET TO OPERATE SET THE THERMOSTAT IN NORMAL
IN ENERGY SAVING MODE OPERATION MODE