GE AH11E/AH11H Install Manual

4 49-5000041 Rev. 4
USING THE AIR CONDITIONER
Controls
ŶPOWER
3UHVVWKH32:(5EXWWRQWRWXUQWKHXQLWRQRURII
:KHQWKHXQLWLVRQWKHSRZHULQGLFDWRUOLJKWZLOOEH
JUHHQ:KHQWKHXQLWLVRIIWKHOLJKWZLOOJRRXW
ŶMODE
3XVKWKLVEXWWRQWRF\FOHWKURXJKWKHPRGHVIURP
&22/+($7)$1&22/7KHLQGLFDWRUOLJKWEHVLGH
WKH³02'(´RSWLRQZLOOLOOXPLQDWHLGHQWLI\LQJWKHPRGH
selected.
&22/7KHUDQJHRIVHWWHPSHUDWXUHLV)a)
Cooling begins automatically when the room
temperature is above the set point,and stops when the
URRPWHPSHUDWXUHLV)EHORZWKHVHWSRLQW%XWWKH
FRPSUHVVRUZLOOUXQPLQXWHVDWOHDVWLQ&22/PRGH
before stopping. The fan runs in continuous mode.
+($77KHUDQJHRIVHWWHPSHUDWXUHLV)a)
For heat pump models the unit can alternate running
between reverse cycle heat mode and electric heater
mode according to the difference between the set
temperature and the room temperature. The fan motor
cycles on and off with the compressor and electric
heater.
NOTE: Reverse cycle heating and electric heater
cannot be run at the same time. In the following cases,
it is normal that the compressor does not operate.
:KHQWKHRXWGRRUWHPSHUDWXUHLVORZHUWKDQ)RU
WKHURRPWHPSHUDWXUHIDOOVWR)EHORZWKHVHWSRLQW
temperature.
7KHUHLVDPLQXWHPLQLPXPFRPSUHVVRUUXQWLPH
at any setting to prevent short cycling. The indoor
fan motors starts before the compressor and stops
after the compressor cycles off.
:KHQIURVWEXLOGVXSWRWKHHYDSRUDWRUFRLOVWKHXQLW
will defrost automatically and the compressor will
cycle off.
)$1)DQRSHUDWLRQRQO\ZLWKRXWKHDWLQJDQGFRROLQJ
NOTE: The set temperature ranges can be changed.
6HH³',36:,7&+(6&21),*85$7,216RQSDJH
for details.
ŶUP/DOWN BUTTONS ( + / - )
3XVKWKH83RU'2:1EXWWRQWRLQFUHDVHRU
decrease) the set temperature of the unit in cooling
or heating mode. The temperature can be set by
LQFUHPHQWVRI)7KHVHWWHPSHUDWXUHDSSHDUVLQWKH
display.
NOTE: 3UHVVDQGKROGDQGEXWWRQVWRJHWKHUIRU
seconds will alternate the temperature display between
&)VFDOH
ŶFAN (FAN SPEED)
(YHU\WLPH\RXSXVKWKLVEXWWRQWKHIDQVSHHGF\FOHV
WKURXJKWKHVHWWLQJVDVIROORZV+,*+0('/2:
Ŷ&2167$17)$1
3URYLGHVFKRLFHRIRSHUDWLQJWKHLQGRRUIDQ
continuously or cycling it on/off with the compressor.
$IDQLFRQDSSHDUVQHDUWKHGLVSOD\ZKHQWKHIDQLV
LQFRQVWDQWPRGH:KHQLQF\FOHPRGHWKHIDQZLOO
operate for several seconds after the compressor
F\FOHVRII7KLVVZLWFKLVQRWDFWLYHLQWKH+HDWPRGH
Ŷ',63/$<6
:KLOHRQ)DQRQO\PRGHLWVKRZVWKHURRP
temperature.
Control code (on some models):
LC 3DGVRQWKHFRQWUROSDQHOLVQRWDYDLODEOH7KH
unit can be operated by using wall thermostat only.
)&3DGVRQWKHFRQWUROSDQHODQGZDOOWKHUPRVWDW
are not available. The unit can be operated by using
)5217'(6.&21752/RQO\
Error codes:
AS5RRPWHPSHUDWXUHVHQVRUHUURU
ES(YDSRUDWRUWHPSHUDWXUHVHQVRUHUURU
CS&RQGHQVHUWHPSHUDWXUHVHQVRUHUURU
OS2XWVLGHWHPSHUDWXUHVHQVRUHUURU
HS([KDXVWWHPSHUDWXUHVHQVRUHUURU
LE:LUHFRWUROOHUHUURU
NOTE: :KHQHUURURFFXUVXQSOXJWKHXQLWDQGSOXJLW
back in.If error repeats, call for service.
2WKHUFRGHV
LO5RRPWHPSHUDWXUHLVORZHUWKDQ)
HI5RRPWHPSHUDWXUHLVKLJKHUWKDQ)
FP/RZWHPSHUDWXUHSURWHFWLRQ
NOTE:$OOWKHLOOXVWUDWLRQVLQWKLVPDQXDODUHIRU
H[SODQDWLRQSXUSRVRQO\<RXUDLUFRQGLWLRQHUPD\EH
slightly different. The actual shape shall prevail.
NOTE: This air conditioner is designed to be operated
XQGHUFRQGLWLRQDVIROORZV
NOTE:
3HUIRUPDQFHPD\EHUHGXFHGLIRXWVLGHWKHVH
operating temperatures.
ÛC
Û)
+
-
Fan
Constant
Fan
Mode
P
ow
e
r
Cool
Heat
Fan
High
Med
Low
Air Conditioner Controls
&RROLQJ2SHUDWLRQ
2XWGRRU7HPS )
,QGRRU7HPS )
+HDWLQJ2SHUDWLRQ
2XWGRRU7HPS )
,QGRRU7HPS )