Quick Specs

H
TX24GASKWS
Hotpoint
®
6.2 cu. ft. capacity aluminized alloy gas dryer
Specification Revised 5/16
Dryer exhausting informationuse metal
duct only vertical and horizontal ducting
A
B
2-1/2
4
GE Dryer Vent
A
B
2-1/2
4
GE Dryer Vent
A
Best performance
Maximum length
of 4" dia rigid
metal duct
Exhaust hood type
Domestic dryer models
Number
of 9
turns
A
4"
opening
B
2-1/2"
opening
Long Vent 6.0 - 8.0 cu. ft.
capacity electric & gas dryers
(HTX21 and HTX24)
0 120 ft. 90 ft.
1 100 ft. 75 ft.
2 85 ft. 65 ft.
3 70 ft. 55 ft.
4 60 ft. 45 ft.
5 55 ft. 35 ft.
For every extra 90° elbow, reduce the allowable vent system length by 10 ft.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to the chart.
When calculating the total vent system length, you must add all the straight
portions and elbows of the system (including the transition duct).
Laundry Center length includes factory-installed elbow that does not impact
vent length.
For complete information, see installation instructions packed with your
dryer.
DUCTING MATERIALS:
For best performance, this dryer should be vented with 4" diameter all
rigid metal exhaust duct. If rigid metal duct cannot be used, then UL-listed
flexible metal (semi-rigid) ducting can be used (Kit WX08X10077). In
special installations, it may be necessary to connect the dryer to the house
vent using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-
type) duct may be used ONLY in installations where rigid metal or flexible
metal (semi-rigid) ducting cannot be used AND where a 4” diameter can be
maintained throughout the entire length of the transition duct. Please see
installation instruction packed with your dryer for complete instructions
when using flexible metal (foil type) ducting.
EXHAUST LENGTH CALCULATION:
1. Determine the number of 90° turns needed for your installation. If you
exhaust to the side or bottom of dryer, add one turn.
2. The maximum length of 4' rigid (aluminum or galvanized) duct which
can be tolerated is shown in the table.
A turn of 45° or less may be ignored. Two 45° turns within the duct
length should be treated as a 90° elbow. A turn over 45° should be
treated as a 90° elbow.
Dryers must be exhausted to the outside.
CAUTION: For personal safety do not terminate exhaust into a chimney,
under any enclosed house floor (crawl space), or into an attic, since the
accumulated lint could create a fire hazard or moisture could cause
damage. Never terminate the exhaust into a common duct or plenum with
a kitchen exhaust, since the combination of lint and grease could create a
fire hazard. Exhaust ducts should be terminated in a dampered wall cap
to prevent back drafts, bird nesting, etc. The wall cap must also be located
at least 12" above the ground or any other obstruction with the opening
pointed down.