Installation guide

3
Installation Instructions
A qualified electrician must perform a ground continuity
check on the wall receptacle before beginning the
installation to ensure that the outlet box is properly
grounded. If not properly grounded, or if the wall
receptacle does not meet electrical requirements
noted (under ELECTRICAL REQUIREMENTS), a
qualified electrician should be employed to correct any
deficiencies.
WARNING
Risk of Electric Shock.
Can cause injury or death:
Remove house fuse or
open circuit breaker
before beginning
installation to avoid
severe or fatal shock
injury.
WARNING
Risk of Electric Shock.
Can cause injury or death: THIS APPLIANCE MUST
BE PROPERLY GROUNDED to avoid severe or fatal
shock.
120 V Models
The power cord of this
appliance is equipped with
a three-prong (grounding)
plug which mates with
a standard three-prong
(grounding) wall
receptacle to minimize
the possibility of electric
shock hazard from this
appliance.
IMPORTANT SAFETY INSTRUCTIONS
ELECTRICAL
REQUIREMENTS
Ensure proper
ground exists
before use
CAUTION
For personal safety, the mounting
surface must be capable of supporting the cabinet
load, in addition to the added weight of this 63–85
pound product, plus additional oven loads of up to
50 pounds or a total weight of 113–135 pounds.
CAUTION
For personal safety, this product
cannot be installed in cabinet arrangements such as an
island or a peninsula. It must be mounted to BOTH a
top cabinet AND a wall.
CAUTION
To avoid the risk of personal injury
(back injury or other injuries due to excessive
weight of the microwave oven) or property damage,
you will need two people to install this microwave
oven.
Where a standard two-prong wall receptacle is
encountered, it must be replaced with a properly
grounded three-prong wall receptacle, installed by
a qualified electrician.
WARNING
Risk of Electric Shock.
Can cause injury or death: DO NOT, under any
circumstances, cut, deform or remove any of the
prongs from the power cord. Do not use with an
extension cord. Failure to comply may cause fire.
120 V Models
This product requires a three-prong grounded outlet.
Product rating is 120 volts AC, 60 Hertz, 15 amps,
and 1.70 kilowatts. This product must be connected
to a supply circuit of the proper voltage and frequency.
Wire size must conform to the requirements of the
National Electrical Code or the prevailing local code
for this kilowatt rating. The power supply cord and
plug should be brought to a separate 15 to 20 ampere
branch circuit single grounded outlet. The outlet box
should be located in the cabinet above the oven and
away from any potential microwave oven ducting.
The outlet box and supply circuit should be installed
by a qualified electrician and conform to the National
Electrical Code or the prevailing local code.