5.7 Installing the stator
On delivery, the stator has already been installed and is ready for operation.
If necessary, the antenna segments can be divided from the antenna
segment clamp for maintenance or to facilitate stator mounting.
We recommend to use the stator ring as it is and to only open if absolutely
necessary.
When the flexible antenna segments are bent, they easily deviate from
circularity.
Prevent the antenna segments from a large deformation while bending.
While opening the stator ring, bend the antenna segments only as wide as
necessary to slip them over a thin part of the shaft nearby.
Fig. 5.5: Bolted connection of the antenna segments on the stator
1. Undo and remove the bolted connections (M4) on the Antenna segment
clamp.
There are fan type lock washers (or toothed washers) between the antenna
segments: Make sure that they do not get lost.
Important
Antenna segment
screws M4
Toothed washer
between the segments
M5 mounting slots for
for fixing the stator ring
Antenna segment
screws M5
Toothed washers
Stator housing
Antenna segments
Antenna segment clamp
and fixation point