Installation Guide

Figure 14
NOTE: If you want to "hard-wire" the blower, contact a certi-
ed electrician.
WARNING:
Unplugging of blower accessory will not stop the heater
from cycling. To shut heater off: Turn temperature dial
or thermostat to lowest setting. Turn knob on gas control
to "OFF," depressing slightly. Do not force.
Oiling
The blower motor does not have oiling holes. Do not attempt to
oil the blower motor.
23820-3-0409
Page 5
Fan Control
The automatic fan control switch is located on the bottom of the
blower assembly. The fan control is a nonadjustable, automatic
type. The fan control will require between 3 and 7 minutes of main
burner operation before the fan control "closes" and activates the
blower. The blower will continue to run between 3 and 7 minutes
after the main burner shuts off, before the fan control "opens" and
deactivates the blower.
Wiring
The appliance, when installed, must be electrically grounded in ac-
cordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70 or Canadian Electrical
Code, CSA C22.1, if an external electrical source is utilized. This
appliance is equipped with a three-prong [grounding] plug for
your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do
not cut or remove the grounding prong from this plug. For an
ungrounded receptacle, an adapter, which has two prongs and a
wire for grounding, can be purchased, plugged into the ungrounded
receptacle and its wire connected to the receptacle mounting screws.
With this wire completing the ground, the appliance cord plug can
be plugged into the adapter and be electrically grounded.