Owner's manual
S351 Control / Timer Relay
Timing Function with  Timing Function with 
Control Functions
latching trigger momentary trigger
Commutating Relay
Bell cut off timer Reset pulse
Setup
Setup Setup
The function control terminals C and D 
The function control terminals, D is The function control terminals, C is 
are not connected. The Relay control R 
connected to +ve and C is not connected to +ve and D is not 
and the timing range T1 and T2 are 
connected. The relay control input R is  connected. The relay control input R is 
also not connected and have no 
linked. linked. 
function. The POT has no function.
Timing ranges Timing ranges
Operation
Without a link in T1 and T2 is the lower  Without a link in T1 and T2 is the lower 
Apply a trigger. The relay changes over 
range from less than 1 second up to 60  range from less than 1 second up to 60 
and the led indicates green. This will 
seconds. When T1 and T2 are linked,  seconds. When T1 and T2 are linked, 
remain until the first trigger is removed 
this is the upper range from less than 1  this is the upper range from less than 1 
and a second trigger is applied, then 
minute up to 60 minutes.  minute up to 60 minutes. 
the relay will switch back and the led 
Operation Operation
indicates red, until the trigger is 
Apply a trigger, the led illuminates Apply a trigger, the led illuminates 
removed when the led will extinguish.
green, but the relay doesn’t switch. If  green, but the relay doesn’t switch. If 
the trigger is removed, the led the trigger is removed, the timing 
A-stabling Relay
extinguishes and the timing is stopped.  continues.  When  the  time  period 
Setup
If the time period expires while the expires with the trigger removed, then 
The function control terminals C and D 
trigger is still applied, then the relay the  relay  switches and  the  led 
are both connect to +ve. The Relay 
switches and the led illuminates red. illuminates red. This will remain for 1 
control R is not connected and has no 
This will remain until the trigger is second, then the relay will switch back 
function. 
removed. and the led extinguish.
Rate of A-stable. 
Without a link in T1 and T2 is the lower 
Max time switch Pulse stretching
range from less than 1 second up to 10 
Setup Setup
seconds. When T1 and T2 are linked, 
The function control terminals, D is The function control terminals, C is 
this is the upper range from 3 to 60 
connected to +ve and C is not connected to +ve and D is not 
seconds.
connected. The relay control input R is  connected. The relay control input R is 
Operation
not linked.  not linked. 
Apply a trigger and the relay will a-
Timing ranges as above. Timing ranges as above.
stable. When the relay is switched the 
Operation Operation
led illuminates green and when the 
Apply a trigger, the led illuminates Apply a trigger, the led illuminates 
relay is un-switched, the led 
green, and the relay switches. If the green, and the relay switches. If the 
illuminates red. When the trigger is 
tr ig ge r i s r em ov ed , t he  le d trigger is removed, the timing 
removed, the relay will stop a-stabling, 
extinguishes, the relay switches back  continues.  When  the  time  period 
reset to the un-switched sate and the 
and the timing is stopped. If the time  expires with the trigger removed, the 
led will extinguish.
period expires while the trigger is still  relay  switches  back  and  the  led 
applied, then the relay switches  back  illuminates red for 1 second and then 
and the led illuminates red. This will extinguishes.
remain until the trigger is removed.
The trigger terminals, A is a -ve applied to trigger, B is +ve applied to trigger.
Note
This unit requires 12v dc to power it at all times. (10-14v dc).
Note 1
If the input is not removed when the timing has finished in 
both momentary trigger modes, then the led will remain 
illuminated red and the relay will remain in the state that it 
was when the led illuminated red until the trigger is removed.
Contact ratings
 The relay is DPCO rated 1Amp @ 12v dc. It must not be 
used to switch mains voltages. 
MAX
MIN
T
R
+ - A B C D
T1
NO NO
RELAY 1 RELAY 2
NC NCCOM COM
T2
LED
12V DC
-VE TRIGGER
Function 
Controls
Timing
Range
+VE TRIGGER
Relay
Control
60043 Iss 5 May 07