User's Manual

Microinverter user manual
15
Output Data (AC)
Rated output power (W)
1000
Rated output current (A)
4.17@240V a.c.,4.81@208V a.c.
Nominal output voltage/range (V)
240/211.2-264,208/183-228.8
Nominal frequency/range (Hz)
60/59.3-60.5
Power factor
>0.99
Output current harmonic distortion
<3%
Max. inverter backfeed current to the
array (A)
0
Maximum output overcurrent
protection (A)
20
Maximum output fault current
55.2 Apk, 184.67 ms of duration, 7.46
Arms
Maximum Units per 20A Branch
4@240V a.c., 3@208V a.c.
Efficiency
Peak inverter efficiency
96.5%
CEC weighted efficiency
96.0%
Nominal MPPT efficiency
99.8%
Night time power consumption (mW)
<50
Mechanical Data
Ambient temperature range ()
-40 ~ +65
Storage temperature range ()
-40 ~ +85
Relative humidity (%RH)
0-100% condensing