user manual
8-4 HP Jetdirect Configuration Page Messages
Table 8.2 General HP Jetdirect Messages (1 of 15)
Message Description
ARP DUPLICATE IP
ADDRESS
The ARP layer has detected another node on
the network using the same IP address as the
HP Jetdirect print server. Extended error information
below this message shows the hardware address of the
other node.
BABBLE ERROR Run the power-on self-test: turn the printer off, then on
again. If the error persists, call the Customer Care
Center (see Chapter 1 for telephone numbers).
BAD BOOTP REPLY An error was detected in the BOOTP reply that the
HP Jetdirect print server received. The BOOTP reply
either had insufficient data in the UDP datagram to
contain the minimum BOOTP header of 236 bytes, had
an operation field that was not BOOTPREPLY(0X02),
had a header field that did not match the print servers
hardware address, or had a UDP source port that was
not the BOOTP server port (67/udp).
BAD BOOTP TAG
SIZE
The tagsize in a vendor specific field in the BOOTP
reply is either 0, or greater than the remaining number
of unprocessed bytes in the vendor specified area.
BAD LENGTH
RCVD:
Total number of frames missed because they were too
long for the HP Jetdirect print server to receive.
BAD PACKETS
RCVD:
Total number of frames (packets) received by the
HP Jetdirect print server with errors.
BOOTP IN
PROGRESS
The HP Jetdirect print server is currently in the process
of obtaining its basic IP configuration information
through BOOTP, and has not detected any errors.
CF ERR - ACCESS
LIST EXCEEDED
The TFTP configuration file specified too many access
list entries using the “allow:” keyword.
CF ERR - FILE
INCOMPLETE
The TFTP configuration file contained an incomplete
last line that did not end in a newline character.
CF ERR - INVALID
PARAM
A line in the TFTP configuration file contained an invalid
value for one of the parameters on that line.
0Book-asF01.book Page 4 Tuesday, August 14, 2001 2:06 PM