Operation Manual
110  Section 9: Branching and Looping 
File name: hp 12c_user's guide_English_HDPMBF12E44  Page: 110 of 209   
Printered Date: 2005/7/29    Dimension: 14.8 cm x 21 cm 
Keystrokes Display   
gi07 
04- 43, 33  07
If condition is true, branches to 
program line 07. 
:2 
05- 45  2
If condition is false, recalls 25% tax 
rate to X-register. 
gi08 
06- 43, 33  08
Branches to program line 08. 
:1 
07- 45  1
Recalls 20% tax rate to X-register. 
b 
08-   25
Calculates tax. 
fs 
–12.36 
Sets calculator to Run mode. 
(Display shows results of running of 
previous program.) 
Now, we'll store the required numbers in registers R
0
, R
1
, and R
2
, then we’ll run the 
program, using 
Ç
 so that we can check that the branching occurs properly. It’s 
good practice with programs containing conditional test instructions to check that 
the program branches correctly for all possible conditions: in this case, if the 
income is less than, equal to, or greater than the test value. 
Keystrokes Display   
20000?0 
20,000.00 
Stores test value in register R
0
. 
20?1 
20.00 
Stores 20% tax rate in register R
1
. 
25?2 
25.00 
Stores 25% tax rate in register R
2
. 
15000 
15,000. 
Keys income less than test value into 
display and X-register. 
Ê 
01- 45  0
Line 01: 
:
0. 
20,000.00 
Test value has been recalled to 
X-register, moving income to 
Y-register. 
Ê 
02-   34
Line 02: 
~
15,000.00 
Income has been placed in 
X-register and test value has been 
placed in Y-register. 
Ê 
03- 43  34
Line 03: 
go
15,000.00 
Ê 
04- 43, 33  07
Condition tested by 
o
 was true, 
so program execution continued 
with line 04: 
gi
07. 