Maintenance and Service Guide
Table Of Contents
- Product overview
- Standard features
- Integrated features
- Stand options
- HP Engage One Basic I/O Connectivity Base components
- HP Engage One Advanced I/O Connectivity Base components
- Connecting an AC adapter to power
- Locating the Engage One power button
- Locating the I/O connectivity base power button
- Adjusting the Engage One head unit
- Engage One serial number location
- I/O connectivity base serial number location
- Illustrated parts catalog
- Routine care, SATA drive guidelines, and disassembly preparation
- Removal and replacement procedures
- Preparation for disassembly
- Attaching an I/O connectivity base to the Engage One
- Connecting a standalone I/O connectivity base to the Engage One
- Configuring the I/O connectivity base’s powered serial ports
- Connecting a standalone optional fingerprint reader to the I/O connectivity base
- Attaching an optional fingerprint reader to the I/O connectivity base
- Removing and attaching the Engage One head unit to the stand
- Mounting the Engage One head unit to a wall
- Mounting the Engage One to a counter top
- Installing a security cable on the I/O connectivity base
- Installing a security cable on the Engage One column
- Installing a security screw on the Engage One head unit and stand
- Installing a security screw on the Engage One head unit and VESA mount
- Removing and replacing the column printer
- Removing the display panel
- System board components
- Installing a 2 x 20 customer-facing display (CFD)
- Memory modules
- Removing and installing an M.2 solid-state drive (SSD)
- Removing the WLAN module
- Removing the heat sink
- Removing the fan assembly
- Removing the speakers
- Removing the power button board
- Removing the MSR (Magnetic Stripe Reader)
- Removing the MSR LED board
- Removing the system board
- Removing the antennas
- Using the column printer
- Cable routing configurations
- Cable matrix for Engage One with integrated column printer and basic I/O connectivity base
- Cable matrix for Engage One with integrated column printer and advanced I/O connectivity base
- Cable matrix for Engage One without I/O connectivity base
- Cable matrix for Engage One with I/O connectivity base
- Cable matrix for Engage One with basic I/O connectivity base and standalone printer
- Cable matrix for Engage One with advanced I/O connectivity base and standalone printer
- Configuring the software
- Computer Setup (F10) Utility
- POST error messages and diagnostic front panel LEDs and audible codes
- Password security and resetting CMOS
- Using HP PC Hardware Diagnostics (UEFI)
- Troubleshooting without diagnostics
- Safety and comfort
- Before you call for technical support
- Helpful hints
- Solving retail system-specific problems
- Solving general problems
- Solving printer problems
- Solving hardware installation problems
- Solving network problems
- Solving memory problems
- Solving USB flash drive problems
- Solving Internet access problems
- Solving software problems
- System backup and recovery
- Power cord set requirements
- Statement of memory volatility
- Specifications
- Index

Apply the cleaner with a soft, lint-free cloth. Avoid using gritty cloths. Always dampen the cloth and then
clean the sensor. Be sure to spray the cleaning liquid onto the cloth, not the sensor, so that drips do not seep
inside the display or stain the bezel.
MSR maintenance
To clean the MSR (magnetic strip reader), swipe a standard cleaning card through the MSR a couple of times.
You can order a standard cleaning card online. You can also put a thin oil-free cloth around a credit card.
Service considerations
Listed below are some of the considerations that you should keep in mind during the disassembly and
assembly of the computer.
Tools and software requirements
To service the computer, you need the following:
●
Torx T-15 screwdriver
●
Flat-bladed screwdriver (may sometimes be used in place of the Torx screwdriver)
●
Phillips #2 screwdriver
●
Phillips #1 screwdriver
●
Diagnostics software
●
Tamper-resistant T-10 screwdriver
Screws
The screws used in the computer are not interchangeable. They may have standard or metric threads and may
be of dierent lengths. If an incorrect screw is used during the reassembly process, it can damage the unit. HP
strongly recommends that all screws removed during disassembly be kept with the part that was removed,
then returned to their proper locations.
CAUTION: As each subassembly is removed from the computer, it should be placed away from the work area
to prevent damage.
Cables and connectors
Most cables used throughout the unit are at, exible cables. These cables must be handled with care to
avoid damage. Apply only the tension required to seat or unseat the cables during insertion or removal from
the connector. Handle cables by the connector whenever possible. In all cases, avoid bending or twisting the
cables, and ensure that the cables are routed in such a way that they cannot be caught or snagged by parts
being removed or replaced.
CAUTION: When servicing this computer, ensure that cables are placed in their proper location during the
reassembly process. Improper cable placement can damage the computer.
Lithium coin cell battery
The battery that comes with the computer provides power to the real-time clock and has a minimum lifetime
of about three years.
MSR maintenance 15